Chapter 2 • Testing, Troubleshooting, and Maintenance
Ignore this screen for installation purposes.
15. Press the down arrow or the Enter button
Ignore this screen for installation purposes.
16. Press the down arrow or the Enter button
The Acq Log displays 24 bits (in three groups of eight) representing
the hourly check-in for the last 24 hours. A one (1) indicates that the
hourly check-in was successful and a zero (0) indicates that it was not.
The least significant bit (bottom right) indicates the past hour check-in
status. Each hour the bits are shifted one position to the left. In the
example below, the ORION successfully checked in the past hour, but
did not for each of the previous three hours.
Press the
On/Off button to turn the HHTR Off.
Field Troubleshooting
The most likely field troubleshooting scenario is a failure of the power up
LED to flash. If the LED on theTWACS-ORION system is not flashing,
ensure that the TWACS-enabled meter is receiving the appropriate power
according to its specific form and voltage (refer to Installation on page 21).
You may use a Remote Test Set (RTS) for further testing or return the meter
to the Meter Shop for further diagnostics.
Last Ch: N/A
RF Link Data:
Acq Failures: 0
Orion Com Status
Orion Com Status
Lnk Abandonment: N/A
RF Link Data:
Error Code: N/A
Orion Com Status
RF Link Data: 24 Hr
Acq Log:
00000000 00000000
00000000
Acq Log: 11111111
11111101 11110001