Installation Instructions
Table Of Contents
- Table of Contents
- 471-2000.pdf
- 471-2001.pdf
- 471-2002.pdf
- 471-2003.pdf
- 471-2004.pdf
- 471-2005.pdf
- 471-2006.pdf
- 471-2007.pdf
- 471-2008.pdf
- 471-2009.pdf
- 471-2010.pdf
- 471-2011.pdf
- 471-2012.pdf
- 471-2013.pdf
- 471-2014.pdf
- 471-2015.pdf
- 471-2016.pdf
- 471-2017.pdf
- 471-2018.pdf
- 471-2019.pdf
- 471-2020.pdf
- 471-2021.pdf
- 471-2022.pdf
- 471-2023.pdf
- 471-2026.pdf
- 471-2027.pdf
- 471-2028.pdf
- 471-2029.pdf
- 471-2030.pdf
- 471-2031.pdf
- 471-2032.pdf
- 471-2033.pdf
- 471-2034.pdf
- 471-2035.pdf
- 471-2036.pdf
- 471-2037.pdf
- 471-2038.pdf
- 471-2040.pdf
- 471-2041.pdf
- 471-2042.pdf
- 471-2043.pdf
- 471-2044.pdf
- 471-2045.pdf
- 471-2046.pdf
- 471-2047.pdf
- 471-2051.pdf
- 471-2052.pdf
- 471-2053.pdf
- 471-2054.pdf
MTU Instruction
for American Meter Company Gas Meters
Purpose & Scope
This instruction provides a procedure for installing a STAR direct-mount MTU on American
Meter Company 5B-225 meters.
Parts Required
Ref. # Item Part Number Quantity
1 Cork Gasket 066-12466B 1
2 Adaptor Plate 056-12466A 1
3 Rubber Gasket 066-12466A 1
4 MTU, Direct Mount per project 1
5 Coupler, MTU 056-5155E2 1
6 Extended Shaft 056-12466B 1
7 Coupler, MTU with Magnet (Magnet 036-0002) 056-5155E2 1
8 #8 x 3/8” Combo Head Sheet Metal Screw, Zinc 069-080012C4A 2
9 ¼-20 x 1 5/8” Slotted Fillister Head Machine Screw 069-142040GA 2
10 Register Cover 109-7712A 1
11 #10 x 1” Combo Head Sheet Metal Screw, Zinc 069-100032C3A 2
471-2034 - 7/18/2007