Purpose & Scope
This instruction provides a procedure for installing a STAR direct-mount MTU on the
following Rockwell/Equimeter/Sensus meters: R175, R200, R250, R275, R310, R315,
RT210.
Parts Required
Ref. # Item Part Number Quantity
1 Gasket (pre-applied to MTU) 066-5155C 1
2 Blue Coupler, MTU 056-5155E 2
3 Retaining Shaft, MTU 056-5155D 1
4 MTU, Direct Mount per project 1
5 Magnet 036-0002 1
6 Gear, Blue, Standard 056-5155G4 1
7 #6 Round Spacer, Nylon 068-60812-EX 2
8 10-24 x 1 1/8” Slotted, Fillister Head Machine Screw 069-102436H 4
9 #10 Flat Washer, Acetal 069-3019 1
10 #6 x 1 1/4” Combo Panhead Sheet Metal Screw 069-060040C3 2
11 Register Cover, MTU 109-7712A 1
12 #10 x 3/4” Tri-lobular Screw 069-101424A2 2
13 Gear, Red, Extended 056-5155G3 1
14 Gear, Yellow, Odometer 056-5155G2 1