MTU Instruction
for Rockwell/Equimeter/Sensus Gas Meters
Step 6– Insert the two ¼-20 x 1-1/4”
machine screws into the holes on the
MTU as shown.
Step 7 – Turn the MTU over and position
the rubber gasket over the screws and
female coupler as shown.
Step 8 - Position the MTU on the meter,
sliding the female coupler over the drive
gear on the meter. Tighten the MTU
mounting screws to 12 to 15 in-lb.
Check the coupler. It should have slight
play — it should not bind or turn too
freely.
CAUTION!
Do not over tighten screws.
Excessive torque may
damage the MTU enclosure.
Power tools are not
recommended for use on
steps 8-12.
Page 155