Installation Instructions

Table Of Contents
MTU Instruction
for Rockwell/Equimeter/Sensus Gas Meters
Step 9 - On the register, insert the two #6
x 1-1/4” sheet metal screws and spacers
as shown.
Step 10 - Mount the register to the MTU,
fastening it to the mounting holes shown
below. Hand tighten to a torque not to
exceed 3-5 inch-pounds. Make sure the
index register gear and the MTU coupler
gear are engaged.
Step 11 - Place the new cover over the
register so that the top label or arrow is
on top and the vent holes are on the
bottom. Align the cover with the mounting
holes on the MTU, press it into place, and
insert the #10 x 1” screws. Hand tighten
to a torque not to exceed 3-5 inch-
pounds. The gasket should be
compressed slightly.
Step 12 - Replace any anti-tamper,
safety, or security hardware onto the
plastic cover as required.
Step 13 – Once Installation is complete,
program the MTU using the STAR
Programmer Software and your MTU
Programmer.
Page 156