Purpose & Scope
This instruction provides a procedure for installing a STAR direct-mount MTU on the
following Rockwell/Equimeter/Sensus 175S meters.
Parts Required
Ref. # Item Part Number Quantity
1 Gasket, Adaptor Plate to Meter 066-0032 1
2 Adaptor Plate, 175S 056-12330CC 1
3 10-24 x 1/2” Slotted, Fillister Head Machine Screw, Zinc 069-102416HA 4
4 Coupler, Female, 12 Tooth 175S 056-12330B 1
5 Coupler Shaft, MTU 056-5155D 1
6 Gasket, Adaptor Plate to MTU 066-12330C 1
7 MTU, Direct Mount per project 1
8 12 Tooth Gear, Male, 175S 056-12330A 1
9 Magnet 036-0002 1
10 10-24 x 1-1/8” Slotted, Fillister Head Machine Screw, Zinc 069-102436HA 4
11 #6 Round Spacer, Nylon 068-0051 2
12 #6 x 1 1/4” Combo Head Sheet Metal Screw, Zinc 069-060040C3A 2
13 Register Cover, MTU 109-7712A 1
14 #10 x 1” Combo Head Sheet Metal Screw, Zinc 069-100032C3A 2