Purpose & Scope
This instruction provides a procedure for mounting a STAR MTU to a Nicor Type A, Type
C or Type X composite pit lid. This procedure covers the mounting of an Original Flatpak
STAR MTU or the New Flatpak STAR MTU to these pit lids. This procedure does not
detail the wiring of the MTU to the meter inside of the pit. Please refer to Publication 471-
2000, General Installation and Wiring Guidelines in addition to any meter specific MTU
installation and programming instructions.
Parts Required
Item Part Number Quantity
MTU As required for installed
meter
1
#8 x 1-1/4” Truss Head Phillips Sheet Metal Screw, 18-8
stainless steel (McMaster # 93406A201)
2 per Original
Style MTU
installation
Spacers (for pit lid mounting of New Style Flatpak MTUs) 056-8150S
2 per New
Style MTU
installation
#8 x 2” Phillips Pan Head Sheet Metal Screw, 18-8 stainless
steel (McMaster #92470A205)
2 per New
Style MTU
installation
Tools Required
To mount the MTU to these pit lids, you
will need the following tools and
equipment:
Safety goggles
#3 Phillips driver bit
Cordless Drill 3/8”, variable speed,
with adjustable torque settings.
Note on setting the torque range: On a
drill-driver that has about 20 settings
(positions), set the adjustment to #6. Use
the lower speed range of the drill-driver.
This should amount to approximately 8 in-
lbs of torque. Reference the operating
instructions for your particular drill to
more accurately determine what setting to
use to achieve a torque range of
approximately 8 in-lbs.
471-2023 - 4/3/2006