for American Model AL800-AL5000 Gas Meters
Step 9 – Fasten the pulser to the meter
body using the four #18-18 x 2.6” slotted,
stainless steel round head bolts provided.
Install security cups, if desired, as shown
below.
Step 10 – If the index box assembly has
a silicone gasket applied around its
bottom edge and that gasket is in good
shape, you can discard the index cover
gasket supplied with the pulser and skip
to Step 11. Otherwise, place the index
cover gasket on the pulser, aligning the
gasket as shown below.
NOTE: When using the cork gasket
supplied with the pulser, be sure that the
bottom edge of the index box is clean and
free of any silicone and/or dirt particles.
Step 11 – Place the index box assembly
on the pulser, aligning the the drive foot
with the two-pin drive disk. Fasten the
index box to the meter with the two #12-
24 x 2-¼” slotted, stainless steel fillister
head screws provided.
Installation of the pulser is now complete.
If you will be remotely mounting the MTU,
refer to Publication 471-2000, General
Installation and Wiring Guidelines for
general information covering the wiring
and mounting of STAR MTUs. Continue
to Step 12 if you will be mounting the
MTU to the pulser body.
NOTE: The pulser and MTU can be
supplied pre-wired or as separate
assemblies. If provided as separate
components, connect the three wires in
the pulser cable (red, black, and white) to
the corresponding wires in the MTU
cable.
Page 110