User's Manual

Table Of Contents
MTU Instruction
for Sprague/Actaris 'Curb-type' Gas Meters
Purpose & Scope
This instruction provides a procedure for use in installing a Hexagram STAR MTU and
Pulser on a Sprague/Actaris ‘Curb-type’ Gas Meter with top mounted index.
Parts Required
Ref Item
Part
Number
Qty
1
#10-32 x 2” slotted
fillister head machine
screw, br
ass
069-
103264HC
4
2 Register (Index) Cover 056-0561 1
3 Cover Gasket,
notched
066-0037 1
4 #6-19 x ½” Phillips
pan head, hi-low
thread forming screw,
stainless
069-
060016A4S
2
5 Single-pin Index Drive,
with Magnet
056-11583D 1
6 Shaft, standard 056-5155D 1
7 MTU/Pulser Assembly 506-11703 1
8 Coupler 056-11703B 1
9 Neoprene rubber
gasket
066-0035 1
Tools Required
Wire Brush
Screwdriver, #2 Phillips
Screwdriver, 3/8” slotted (flat-
blade)
Two (2) Alignment Studs
Also see Publication 471-2000, General
Installation and Wiring Guidelines for a
complete list of recommended tools and
supplies for MTU Installation.
Installation Procedure
There are two parts to this procedure.
First, the pulser must be mounted to the
meter. Then, the MTU must be mounted
in a nearby location that will allow RF
transmissions to propagate.
471-2033 - 4/28/2008
Page 145