User's Manual

Table Of Contents
MTU Instruction
for Rockwell/Equimeter/Sensus Gas Meters
Tools Required
To mount the MTU to these meters, you
will need the following tools and
equipment:
Cordless drill ”, variable
speed, with adjustable torque
settings
#2 Phillips power screwdriver
bit
Safety goggles
Phillips screwdriver
Slotted screwdriver
Installation Procedure
Before installing the MTU, anti-tamper,
safety, and security hardware must be
removed from the clear register cover.
Step 1 - Remove the existing clear
register cover by removing the four
screws. Discard the screws and cover.
Step 2 - Remove the register by
removing the two screws. Set the register
aside. Discard the screws.
Step 3 – Insure that the cork gasket is
properly applied to the meter (ribbed) side
of the adaptor plate and fasten the
adaptor plate and gasket to the meter
using the four 10-24 x 1/2” machine
screws provided.
Page 158