User's Manual

Table Of Contents
MTU Instruction
for Rockwell/Equimeter/Sensus Gas Meters
Tools Required
To mount the MTU to these meters, you
will need the following tools and
equipment:
Cordless drill ”, variable
speed, with adjustable torque
settings
#2 Phillips bit
Safety goggles
Phillips screwdriver
Slotted screwdriver
Installation Procedure
Before installing the MTU, anti-tamper,
safety, and security hardware must be
removed from the clear register cover.
Step 1 - Remove the existing clear
register cover by removing the four
screws. Discard the screws and cover.
Step 2 - Remove the register by
removing the two screws. Set the register
aside. Discard the screws.
Step 3 - Insert the four 10-24 x 1
screws through the holes on the MTU as
shown.
Step 4 – Turn the MTU over and insure
that there is a pre-applied gasket on the
back of the MTU as shown below.
Note: Couplers are pre-assembled to the
MTU. Insure that the couplers are firmly
attached to the shaft and that the coupler
on the front side of the MTU contains the
magnet. Also, verify that the plastic
washer is in place between the rear
coupler and the MTU.
Step 5 - Position the MTU on the meter.
Rotate the coupler so that the gear tooth
on the coupler engages with the gear
teeth on the gas meter. Orientation is not
critical, but you should be able to feel the
teeth “bite” when you turn the coupler
from the front of the MTU.
Step 6 - Tighten the four 10-24 x 1-
screws to 12 to 15 in-lb. On a standard
drill driver with 0 to 24 torque settings,
this is typically the #10 setting. Tighten
corner to corner.
Step 7 - Check the coupler. It should
have slight play — it should not bind or
turn too freely.
Page 16