for Rockwell/Equimeter/Sensus Gas Meters
Purpose & Scope
This instruction provides a procedure for installing a STAR remote-mount MTU on the
following Rockwell/Equimeter/Sensus meters: R175, R200, R250, R275, R310, R315,
RT210. Please also refer to Publication 471-2000, General Installation and Wiring
Guidelines for general information covering the wiring and mounting of STAR MTUs.
Parts Required
Item Part Number Quantity
MTU, Rockwell Remote Mount, with sensor per project 1
#6 x 3/4” Philips Panhead Sheet Metal Screw 069-06000242A 2
#10-24 x 1-1/2” Slotted, Fillister Head Machine Screw 069-102448HA 4
Tools Required
To mount the MTU to these meters, you
will need the following tools and
equipment:
Safety goggles
Phillips screwdriver
Slotted screwdriver
Installation Procedure
Before installing the MTU, anti-tamper,
safety, and security hardware must be
removed from the clear register cover.
Step 1 - Remove the existing clear
register cover by removing the four
screws that hold it. Set the cover aside.
Discard the screws.
Step 2 - Remove the register by
removing the two screws. Discard the
screws.