User's Manual

Table Of Contents
MTU Instruction
for Rockwell/Equimeter/Sensus Gas Meters
Purpose & Scope
This instruction provides a procedure for installing a STAR direct-mount MTU on
Rockwell/Equimeter/Sensus MR-8 residential gas meters.
Parts Required
Ref. # Item Part Number Quantity
1 Gasket 066-5155C 1
2 Coupler, MTU 056-13183A 1
3 Retaining Shaft, MTU 056-5155D 1
4 MTU, Direct Mount 501-6327/7712 1
5 Magnet 036-0002 1
6 Gear/magnet holder 056-13183B 1
7 10-24 x 1 1/8” Slotted, Fillister Head Machine Screw 069-102436HA 4
8 #6 Round Spacer, Nylon 068-60812-EX 2
9 #6 x 1 1/4” Combo Panhead Sheet Metal Screw 069-060040C3A 2
10 Register Cover, MTU 109-7712A 1
11 #10 x 1” Combo Panhead Sheet Metal Screw 069-100032C3A 2
471-2044 - 4/8/2007
Page 179