MTU Instruction
for Rockwell/Equimeter/Sensus Gas Meters
CAUTION!
Do not over tighten screws.
Excessive torque may
damage the MTU enclosure.
Power tools are not
recommended for use on
steps 9-12.
Step 8 - On the register, insert the screws
and spacers.
Step 9 - Mount the register to the MTU,
fastening it to the mounting holes shown
below. Hand tighten to a torque not to
exceed 3-5 inch-pounds. Make sure the
index register gear and the MTU coupler
gear are engaged.
Step 10 - After you feel engagement
between the index register gear and the
MTU coupler gear, tighten the register
screws until they are snug.
Step 11 - Place the new cover over the
register so that the top label or arrow is
on top and the vent holes are on the
bottom. Align the cover with the mounting
holes on the MTU, press it into place, and
insert the #10 x 1” screws. Hand tighten
to a torque not to exceed 3-5 inch-
pounds. The gasket should be
compressed slightly.
Step 12 - Replace any anti-tamper,
safety, or security hardware onto the p-
lastic cover as required.
Step 13 – Once Installation is complete,
program the MTU using the STAR
Programmer Software and your MTU
Programmer.