User's Manual

Table Of Contents
MTU Instruction
for American Model AL800-AL5000 Gas Meters
Step 3 – Place the adapter plate
contained in the installation parts onto the
head of the meter with the ear holes
aligned over the index plate mounting
holes of the meter head. The embossed
“AL800-AL5000” on the adapter plate is
oriented to the front of the meter.
Step 4 – AFTER PLACING THE
APAPTOR PLATE, Thread the (18-18
thread) ends of the securing studs (4) into
the index cover screw holes of the index
plate. Lightly snug the studs by grasping
them by the flat that is machined into the
top of the stud.
Step 5 - Apply the seal plate over the
studs.
Step 6 – Before setting the IPT over the
mounting studs, you must align the shaft
drive pin of the IPT so that it will engage
inside the fork portion of the meter drive
foot.
Page 76