Specifications

26
The AC synchronous Electrak 2000
provides constant speed motion for
cycling applications, where
programmability is not required.
These actuators provide 100% duty
cycle and can be easily reversed
using limit switches for end of stroke
control. All actuators operate on 115
vac. Models are available with 5 load
ratings. The actuators are also
available in both in-line and parallel
versions for different mounting, size
and load requirements. The required
capacitor is included with each
actuator.
Parallel or In-line Configuration
AC Synchronous Electrak Actuator
Options
Mounting options: Clevis
Front flange plate
Trunion
Side tapped holes
Foot mount
Rod ends: Universal rod end
1/2 – 20 Tapped hole
1/2 – 20 External threaded rod
Brake and For brake or encoder
encoder: consult factory
Actuator Accessories
Sensors for end of stroke indication
(not for direct reversal of motor, requires relays or mechanical
limit switches)
Part Number
N.O. 840-9005
N.C. 840-9008
Specifications
Dynamic Load: Up to 1850 lb. at 0.05 in./sec.
Static Load: Up to 1850 lb.
Speed: Up to .6 in./sec. at 150 lb. load
Duty Cycle: Continuous
Life: Up to 50 million cycles
End Play: 0.010 inch maximum
Limit Switches: Two limit switches standard,
other switches may be added on
three sides of the cover tube
(either relays or mechanical limit
switches are required for
reversing the motors)
Stroke Lengths: 2, 4, 6, 8, 12, 18, 24 inch
standard (for other lengths,
contact the factory)
Ambient Temperature: -40°F to 150°F (-40°C to 65°C)
Motor: AC synchronous 72 RPM