Specifications

28
In-line Configuration
AC Synchronous Electrak Actuator Suitable for Class 1, Group D Locations
Options
Mounting options: Front flange plate
Trunion
Side tapped holes
Foot mount
Rod ends: Universal rod end
1/2 – 20 Tapped hole
1/2 – 20 External threaded rod
Brake and No brake or encoder available
encoder: with H.D. motor
Actuator Accessories
Limit Switches
NO with 50 ft. lead 840-9028
NC with 50 ft. lead 840-9030
Intrinsically Safe Barrier
2 channel AC 904-9105
The AC synchronous Electrak 2000 provides
constant speed motion for cycling applications,
where programmability is not required. The
actuator provides 100% duty cycle and can be
easily reversed using limit switches for end of
stroke control. All actuators operate on 115 vac.
Two models are in-line with load ratings of 250
and 650 pounds. The required capacitor and
resistor are included with each actuator.
“Hazardous Duty” locations as defined by the
National Electrical Code Class 1, Group D
requirements. “Class 1” is designated as
locations in which flammable gasses or vapors
are, or may be, present in the air in quantities
sufficient to cause explosions or ignitable
mixtures. “Group D” includes atmospheres
containing gasoline, petroleum, naphtha,
acetone, lacquer, solvent vapors or natural gas.
Specifications
Dynamic Load: Up to 650 lb. at 0.2 in./sec.
Speed: Up to .6 in./sec. at 250 lb. load
Duty Cycle: Continuous
Life: Up to 50 million cycles
End Play: 0.010 inch maximum
Limit Switches: 1-NO and 1-NC with 50 foot
leads and 2 channel intrinsically
safe barrier included.
Note: Barrier and motor
capacitor must belocated out of
the hazardous area. Any
electrical devices used with the
actuator should have a
designation as suitable for Class
1 Group D areas.
Stroke Lengths: 2, 4, 6, 8, 12, 18, 24 inch
standard (for other lengths,
contact the factory)
Ambient Temperature: -40°F to 150°F (-40°C to 65°C)
Washdown Protected: IP53
Motor: AC synchronous Hazardous
Duty X-700 72 RPM
UL Listed: UL Listed with switches and
barrier.