Specifications

30
In-line Configuration
Programmable Hazardous Duty Electrak Actuator
Options
Mounting options: Front flange plate
Trunion
Side tapped holes
Foot mount
Rod ends: Universal rod end
1/2 – 20 Tapped hole
1/2 – 20 External threaded rod
Brake and No brake or encoder available
encoder: for XP actuator
Actuator Accessories
Programmable Motion Control
Must be mounted out of the hazardous area
Indexer SS2000I
6 amp Drive SS2000D6
Limit Switches
NO with 50 ft. lead 840-9028
NC with 50 ft. lead 840-9030
Intrinsically Safe Barrier
2 channel AC 904-9105
2 channel DC 904-9103
Specifications
Dynamic Load: Up to 625 lb. at 1.5 in./sec.
Static Load: Up to 625 lb.
Speed: Up to 20 in./sec. at 50 lb.
Acceleration: Up to 50 in./sec./sec. at no load
Duty Cycle: Continuous
Life: Up to 50 million cycles
End Play: 0.010 inch maximum
Resolution: 0.0005 based on 1/10 microstep
Repeatability: 0.0005 inches (depending on
mounting)
Limit Switches: 1-NO with 50 foot lead and 2
channel intrinsically safe barrier
included.
Note: Barrier must be located out
of the hazardous area. Any
electrical devices used with the
actuator should have a
designation as suitable for Class
1 Group D areas.
Stroke Lengths: 2, 4, 6, 8, 12, 18, 24 inch
standard (for other lengths,
contact the factory)
Ambient Temperature: -40°F to 150°F (-40°C to 65°C)
Washdown Protected: IP53 (Water spray)
Motor: MX112 Step motor meets the
specification for motors
operating in “Hazardous Duty”
locations as defined by the
National Electrical Code Class 1,
Group D requirements. 50 foot
cable included.
UL Listed: UL Listed with switches and
barrier.
This version of the Electrak 2000 actuator uses a step motor
designed to meet the NEC specifications for motors operating
in Class 1 Group D locations. Two models are offered. The
load/speed chart shows that both actuators will still operate
up to 5 inches per second with a 200 lb. load, while the
high load model can move 625 pounds at 1.5 in./sec.
This in-line ball screw actuator is direct drive and
available with flange, foot trunion and side tapped
holes for a variety of ounting options. The combina-
tion of mounts with rod end options provides either a
very rigid connection for precise applications or a
compliant connection for applications that require
multiple degrees of freedom. The SS2000I indexer and
SS2000D6 drive provides the ability to program and operate
the actuator.
“Hazardous Duty” locations as defined by the National
Electrical Code Class 1, Group D requirements. “Class 1” is
designated as locations in which flammable gasses or vapors
are, or may be, present in the air in quantities sufficient to
cause explosions or ignitable mixtures. “Group D” includes
atmospheres containing gasoline, petroleum, naphtha,
acetone, lacquer, solvent vapors or natural gas.