How to Order
The Electrak 2000 system requires an actuator, a control, a cable to the actuator and a programming option.
To order an Electrak 2000 as a complete system with or without options specify the following information:
1. Select the actuator model number using the part number system for Electrak 2000.
2. Select any additional sensors as needed: Part Number
N.O. without diode (for use with SS2000 controls) 840-9005
N.C. without diode (for use with SS2000 controls) 840-9008
3. Choose the control from the following options:
SS2000D6 & SS2000I – for use with a BP93, BI93 or BI12 type actuator
Verification controls for actuators utilizing encoder feedback
SS2000D6 & SS2000I-V – for use with BP93, BI93 or BI12 type actuator
*Includes I/O board and diodes.
4. Choose the cable between the actuator and control from the following chart:
For actuator encoder to control.
(only for use with verification control)
Cable For SS2000 For SS2000I-V
Length Control Control
10 feet B216022-031 (included) 250-9013 (included with SS2000I-V)
25 feet B216022-032 250-9014
50 feet B216022-033
100 feet B216022-035
5. Choose the programming option from the following:
Software package for use with MS-DOS computer ............. Software package and interface cable
included with each control.
Step motor actuator
Parallel style
Size 34 motor, triple stack
5:1 gear ratio
Acme screw
5/8 diameter screw
.200 lead
6 inch stroke
Foot mount
External threaded rod
Encoder no brake
500 line encoder
Example:
From
performance curves
B P 93 05 - A 6 5 06 - F X E 5