Technical data

LPG VALVES & EQUIPMENT
DIVISION
www.cavagnagroup.com
B
2
EDITION JUNE 2005
The features described in this illustration do not bind the manufacturer.
V R N 2 0 L
66.0.290.1061
This is a special
filler valve, designed
for stationary
underground tanks.
This design facilitates
the connection between
the stationary tank
and the hose
of LPG tank truck.
VRN 93
66.0.290.0221
VRN 90
66.0.290.1051
Filler valve
for LP-GAS tanks.
TUV approved.
Furnished with
solid brass cap.
Filler Valves
FEATURES
- Both these valves are a double check
filler valves where there are a soft seated
upper back check and a (2) metal to metal
lower back check seat
- In addition these filler valves incorporate
an emergency ball shut-off valve
- These two versions can be used either for
underground (VRN 88) or above ground
LPG tanks (VRN 93) thanks to an oriented easy
to connect design to the bobtail delivery truck
- Both valves are conforming British standards
VRN 88
67.0.490.0681
Part number
Tank Filler Wrench
connection connection Hex Flats
10 PSI 20 PSI 25PSI 30 PSI 40 PSI 50 PSI 75 PSI
66.1051 (VRN 90) 1 1/4 - NPT 1 3/4 - 6 ACME Es. 46 mm 58 - 98 - - 146 186
66.1061 (VRN 20L) 1 1/4 - NPT 1 3/4 - 6 ACME Es. 46 mm 54 - 100 - - 148 190
66.0221 (VRN 93) 1 1/4 - NPT 1 3/4 - 6 ACME Es. 46 mm - - - - - - -
67.0681 (VRN 88) 1 1/4 - NPT 1 3/4 - 6 ACME Es. 46 mm - - - - - - -
ORDERING INFORMATION
Propane liquid capacity at various differential pressure (GPM)