Menu 1. Safety Instructions ............................................................................................................................2 2. Technical Specifications ....................................................................................................................3 3. Installation and Connection .............................................................................................................4 4. How to set the unit ..............................................
1. Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual. Important: Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.
DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly. DO NOT touch any wire during operation as there might be a hazard of electric shock. Avoid entanglement of the power cord with other wires. The minimum distance to objects/surface must be more than 1 meters. In the event of serious operating problem, stop using the unit immediately. Never turn on and off the unit time after time. DO NOT open the housing as there are no user serviceable parts inside.
1. Consignes de sécurité Veuillez lire attentivement les instructions qui contiennent des informations importantes sur l'installation, l'utilisation et l'entretien. ATTENTION Veuillez conserver ce guide de l'utilisateur pour une consultation future. Si vous vendez l'appareil à un autre utilisateur, assurez-vous qu'il reçoive également ce manuel d'instructions. Important: Les dommages causés par le non-respect de ce manuel d'utilisation ne sont pas couverts par la garantie.
Assurez-vous que le cordon d'alimentation n'est pas pincé ou endommagé; remplacez-le immédiatement s'il est endommagé. La température de surface de l'unité peut atteindre 65℃. NE PAS toucher les capots à mains nues pendant son fonctionnement. Évitez que des liquides inflammables, de l'eau ou du métal ne pénètrent dans l'appareil. Si cela se produit, coupez immédiatement l'alimentation secteur. NE PAS utiliser le luminaire dans un environnement sale ou poussiéreux.
2. Technical Specifications 13 channel Modes; Ideal for discotheques, clubs, bars, parties, Mobile DJs, etc. Input Voltage: 100-240V~ 50/60Hz Total Power consumption: 1500W Power Cord Daisy Chain: 1Fixtuer(120V); 2 Fixtuer(220V); Beam Angle: 110° IP Grade: IP 65 LED Sources: 0.
3. Installation and Connection The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals.
DOWN To go forward in the selected functions UP To go backward in the selected functions ENTER To confirm the selected functions 3 Breathable punishment ○ 4 Power input/output ○ For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal, and to link the next unit. 5 DMX input/output: ○ For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal, and to link the next unit. 6 Ethernet in/ Ethernet Thru: For ArtNet link ○ 4.
Network Art-Net Settings Sacn Settings Auto Connect Option DMX Art-Net sACN Standard Quiet RDM UID xxxxxxxxxxxx Power Mode Error Logs Fixture Errors Reset Error Log 9H Sacn Settings 1-32000 sACN Priority 0-200
DMX Settings Enter MENU mode, select DMX settings, confirm by pressing ENTER on, and use UP / DOWN on to select: DMX Address, Ethernet Setup and Connect Option. DMX Address Select the DMX Address, press enter to confirm, and the current DMX Address will be displayed on the display screen. Use the UP / DOWN button to select 001 ~ 512 Addresses, and press the ENTER button to save. Press the MENU button to return to the previous MENU or wait 30 seconds to automatically exit the menu mode.
Optically Linear Square Law Inverse-Square Law S-Curve Mode 1(Optically Linear): The increase in light intensity appears to be linear as DMX value is increased. Mode 2(Square Law): Light intensity control is finer at low levels and coarser at high levels. Mode 3(Inverse Square Law): Light intensity control is coarser at low levels and finger at high levels. Mode 4(S-cure): Light intensity control is finger at low levels and high levels and coarser at medium levels.
Manual Test Select the Manual Mode, press the ENTER button to confirm. Use the UP and DOWN button to adjust the value for Red,Green,Blue,White, Intensity, Durate or Rate from 0~255, press the ENTER button to confirm. (DMX signal will be the first priority under Manual Mode.) Once selected, press the ENTER button to store. Press the MENU button back to the last menu without any change or idling 30 seconds to exit menu mode. Auto Test Select Auto Test, press the ENTER button to confirm.
Error Logs To select Error Logs, press the ENTER button to confirm. Use the UP/DOWN button to select Fixture Errors or Reset Error Log, press the ENTER button to store. To select Reset Error Log, press the ENTER button to confirm, use the UP/DOWN button to select No or Yes, press the ENTER button to store.
RDM function table DMX START MANUFAC TURER DEVICE MODEL DESCRIPTION DMX PERSONALITY 0-512 ACME THUNDERSTRUCK DMX 4/4Channel( 8 bit) DMX 8/8Channel (16 bit) DMX 8/8 Channel DMX 52/52 Channel DMX12/1 Piexl DMX16/2V Piexl DMX16/2H Piexl DMX20/3 Piexl DMX24/4 Piexl DMX32/6V Piexl DMX32/6H Piexl DMX56/12 Piexl DEVICE LABEL IDENTIFY DEVICE DEVICE HOURS SOFTWARE RESET DEVICE THUNDERSTRUCK Off/On Warm/Cold 5. How to control the unit 1.
6.
16H
17H
7. DMX512 Connection Mode connection: 1. Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” cable. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system 2. The DMX output and input connectors are pass-through to maintain the DMX circuit when one of the units’ power is disconnected. 3.
B. Not responding to DMX controller 1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the fixture or the previous one. 4. Try to use another DMX controller. 5.
Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2014/30/EU. EN 55032: 2015; EN IEC 61000-3-2: 2019; EN 61000-3-3: 2013 ; EN 55035: 2017.