7. DMX512 Connection
Mode connection:
1. Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture to
the input of the next fixture. The cable cannot be branched or split to a “Y” cable. Inadequate or
damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down
the system
2. The DMX output and input connectors are pass-through to maintain the DMX circuit when one of
the units’ power is disconnected.
3. At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors. Solder
a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in
the DMX-output of the last fixture.
4. Each lighting fixture needs to have an address set to receive the data sent by the controller. The
address number is between 0-511 (usually 0 & 1 are equal to 1).
5. 3/5 pin XLR connectors:.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
8.Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for
easy troubleshooting:
A. The fixture does not work, no light
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.