ASS E NEW ICT TRANSFORMERS LED IN B M Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
INDUSTRIAL CONTROL TRANSFORMERS Industrial control transformers are used to reduce supply voltages to 240V or lower for the operation of electromagnetic devices such as contactors, solenoids, relays, and timers. They are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized without sacrificing secondary voltage stability beyond practical limits.
ASS E TB SERIES Group A LED IN B M 120 X 240 PRIMARY VOLTS — 12/24 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A B C D E Weight (lb)(kg) Wiring Diag. 50 TB50A001① 3.78 (9.60) 3 (7.62) 3.14 (7.98) 1.96 (4.98) 2.5 (6.35) 2.7 (1.22) 1 75 TB75A001① 4 (10.16) 3 (7.62) 4.52 (11.47) 2.42 (6.15) 2.5 (6.35) 3.4 (1.54) 1 100 TB100A001① 4 (10.16) 3.38 (8.59) 4.84 (12.28) 2.42 (6.15) 2.81 (7.14) 4.4 (2.00) 1 150 TB150B001① 4.03 (10.24) 3.
Group D 208/230/460 PRIMARY VOLTS— 115 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) Wiring Diag. VA Rating Catalog Number A 50 TB50A005C*① 3.78 (9.60) 3 (7.62) 3.14 (7.98) 2.21 (5.61) 2.5 (6.35) 2.7 (1.22) 5 75 TB75A005C*① 4 (10.16) 3.38 (8.59) 3.46 (8.79) 2.42 (6.15) 2.81 (7.14) 3.4 (1.54) 5 100 TB100A005C*① 4 (10.16) 3.38 (8.59) 3.46 (8.79) 2.42 (6.15) 2.81 (7.14) 4.4 (2.00) 5 150 TB150B005C*① 4.03 (10.24) 3.75 (9.53) 3.77 (9.58) 2.82 (7.16) 3.13 (7.95) 5.
ASS E Group F LED IN B M 208/500, 220/380/440/550, 230/400/460/575, 240/416/480/600 — PRIMARY VOLTS 85/100/110, 91/110/120, 95/115/125, 99/120/130 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A B C D E Weight (lb)(kg) Wiring Diag. 50 TB50A007C*② 3.44 (8.74) 3.88 (9.86) 3.38 (8.59) 2.42 (6.15) 2.81 (7.14) 4 (1.81) 7 100 TB100A007C*② 4 (10.16) 3.75 (9.53) 3.62 (9.19) 2.99 (7.59) 3.13 (7.95) 6.8 (3.08) 7 150 TB150B007C*② 4 (10.16) 4.5 (11.
Group H 230, 460, 575 PRIMARY VOLTS — 95, 115 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A 50 TB50A011① 75 TB75A011① 100 TB100A011① 4.5 (11.43) 3.38 (8.59) 150 TB150B011① 4.53 (11.51) 3.75 (9.53) 200 TB200B011① 4.38 (11.13) 3.75 (9.53) 3.98 (10.11) D E Weight (lb)(kg) Wiring Diag. B C 4.03 (10.24) 3 (7.62) 2.72 6.9088 2.21 (5.61) 2.5 (6.35) 3.2 (1.45) 11 4.03 (10.24) 3.38 (8.59) 3.04 (7.72) 2.42 (6.15) 2.81 (7.14) 4.2 (1.91) 11 3.
ASS E Group K LED IN B M 240 X 480 PRIMARY VOLTS— 120 X 240 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A 50 TB50A014① 75 TB75A014① 100 TB100A014① 4 (10.16) 3.38 (8.59) 150 TB150B014① 4.03 (10.24) 3.75 (9.53) 200 TB200B014① 4.38 (11.13) 4.5 (11.43) 3.97 (10.08) B C 3.78 (9.60) 3 (7.62) 4 (10.16) 3 (7.62) Weight (lb)(kg) Wiring Diag. D E 2.72 6.9088 1.96 (4.98) 2.5 (6.35) 2.7 (1.22) 14 3.14 (7.98) 2.42 (6.15) 2.5 (6.35) 3.4 (1.
Group M 550/575/600 PRIMARY VOLTS —110/115/120 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A 50 TB50A017C*① 3.78 (9.60) 3 (7.62) 75 TB75A017C*① 4 (10.16) 3 (7.62) 100 TB100A017C*① 4 (10.16) 3.38 (8.59) 150 TB150B017C*① 4.03 (10.24) 3.75 (9.53) 200 TB200B017C*① 4.38 (11.13) 4.5 (11.43) 4.4 (11.18) 250 TB250B017C*① 4.38 (11.13) 4.5 (11.43) 4.4 (11.18) 300 TB300B017C*① 4.75 (12.07) 4.5 (11.43) 4.4 (11.18) 350 TB350B017C*① 4.75 (12.07) 4.
ASS E CE SERIES INDUSTRIAL CONTROL TRANSFORMERS FOR GLOBAL APPLICATIONS LED IN B M The Acme Electric CE Series Industrial Control Transformers are designed specifically for machine tool control circuit applications. These transformers have the ability to handle potentially damaging high in-rush currents that occur when electromagnetic components are energized, without sacrificing the required stable output voltage.
Group P 200, 208/220, 230, 240/440, 460, 480 PRIMARY VOLTS — 23, 24, 25/110, 115, 120 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A 50 CE50A004 75 CE75A004 100 CE100A004 150 CE150B004 200 CE200B004 B C 3.38 (8.59) 3 (7.62) 3.38 (8.59) 3.38 (8.59) 3.63 (9.22) 3.75 (9.53) 3.75 (9.53) 4.5 (11.43) 4.38 (11.13) 4.5 (11.43) Weight (lb)(kg) Wiring Diag. D E 3.25 (8.26) 2.21 (5.61) 2.81 (7.14) 4.2 (1.91) 4 3.5 (8.89) 2.42 (6.15) 3.13 (7.
ASS E Group R LED IN B M 220 X 440, 230 X 460, 240 X 480 PRIMARY VOLTS — 110/115/120 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A 50 CE50A008 3.38 (8.59) 3 (7.62) 3 (7.62) 2.42 (6.15) 2.5 (6.35) 3.4 (1.54) 8 75 CE75A008 3.46 (8.79) 3.38 (8.59) 3.25 (8.26) 2.42 (6.15) 2.81 (7.14) 4.8 (2.18) 8 100 CE100A008 3.38 (8.59) 3.75 (9.53) 3.5 (8.89) 2.42 (6.15) 3.13 (7.95) 5.9 (2.68) 8 150 CE150B008 3.75 (9.53) 4.5 (11.43) 4 (10.16) 2.42 (6.
Group U 240 X 480 PRIMARY VOLTS — 24 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A 50 CE50A013 3.38 (8.59) 3 (7.62) 3 (7.62) 2.21 (5.61) 2.5 (6.35) 3.4 (1.54) 13 75 CE75A013 3.38 (8.59) 3.38 (8.59) 3.25 (8.26) 2.21 (5.61) 2.81 (7.14) 4.2 (1.91) 13 100 CE100A013 3.38 (8.59) 3.75 (9.53) 3.5 (8.89) 2.42 (6.15) 3.13 (7.95) 5.9 (2.68) 13 150 CE150B013 4 (10.16) 4.5 (11.43) 4 (10.16) 2.42 (6.15) 3.75 (9.53) 8.5 (3.
ASS E Group X LED IN B M 550/575/600 PRIMARY VOLTS — 110/115/120 SECONDARY VOLTS — 1Ø 50/60 Hz Dimensions (inches)(cm) VA Rating Catalog Number A 50 CE50A017 3.38 (8.59) 3 (7.62) 3 (7.62) 2.42 (6.15) 2.5 (6.35) 3.4 (1.54) 17 75 CE75A017 3.38 (8.59) 3.38 (8.59) 3.25 (8.26) 2.42 (6.15) 2.81 (7.14) 4.8 (2.18) 17 100 CE100A017 3.38 (8.59) 3.75 (9.53) 3.5 (8.89) 2.42 (6.15) 3.13 (7.95) 5.9 (2.68) 17 150 CE150B017 3.75 (9.53) 4.5 (11.43) 4 (10.16) 2.42 (6.15) 3.75 (9.
TB/CE SERIES WIRING DIAGRAMS 1 2 5 6 9 14 10 3 4 7 8 10A 11 15 12 13 14 16 17 18
ASS E INDUSTRIAL CONTROL TRANSFORMERS FOR HARSH ENVIRONMENTS LED IN B M Designed for control panels where internal installation of Control Transformers is prohibited Some specifications require installation of large control transformers, usually 1000 to 5000 VA outside the control cabinet. This means the transformer must be in a sheet metal enclosure instead of the usual open core and coil construction method.
ASS BLED IN M E Follow us on N56 W13355 Silver Spring Drive Menomonee Falls, WI 53051 800.334.5214 hubbell.com/acmeelectric/en Hubbell Canada Inc. 905-839-1138 Hubbell de Mexico, S.A. de C.V. 52-55-9151-9999 © 2018 Acme Electric All Rights Reserved.