User guide

3.2.3 Isolated Digital Output Connector
The system is equipped with an 8-channel digital output connector that meets requirements
for a system customary automation control. The digital I/O can be configured to control cash
drawers and sense warning signals from an Uninterrupted Power System (UPS), or perform
store security control. You may use software programming to control these digital signals.
Open drains Output, 12V~24V Max sink 200mA.
Pin
Signal
1
XOUTCOM+
2
XOUT0
3
XOUT1
4
XOUT2
5
XOUT3
6
XOUT4
7
XOUT5
8
XOUT6
9
XOUT7
10
XOUTCOM-
DO Contact Wiring