FPC-8057 5.
Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Acnodes Corp. assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Acnodes Corp assumes no responsibility for any inaccuracies that may be contained in this document. Acnodes Corp makes no commitment to update or to keep current the information contained in this manual.
ESD Precautions Integrated circuits on computer boards are sensitive to static electricity. To avoid damaging chips from electrostatic discharge, observe the following precautions: • Do not remove boards or integrated circuits from their anti-static packaging until you are ready to install them. • Before handling a board or integrated circuit, touch an unpainted portion of the system unit chassis for a few seconds. This helps to discharge any static electricity on your body.
Unpacking The FPC-8057 is packed in an anti-static bag. The product has components that are easily damaged by static electricity. Do not remove the anti-static wrapping until proper precautions have been taken. Safety instructions in front of this User’s Manual describe anti-static precautions and procedures. After unpacking the product, place it on a raised surface and carefully inspect the board for any damage that might have occurred during shipment.
Safety Instructions O verview This section states the safety instructions, which must be followed when installing, operating and servicing the FPC-8057. If neglected, physical injury and death may follow, or damage may occur to controller and related equipment. The material in this chapter must be studied before attempting any work on, or with, the unit. Warnings and Notes This manual distinguishes safety instructions.
damage equipment. General warning: Warns of situations, which can cause physical injury and or damage equipment by means other than electrical. Electrostatic Discharge Warning: Warns of situations in which an electrostatic discharge can damage equipment. Readers are notified of the need for special attention or additional in formation available on the subject with the following symbols: CAUTION! Note: Aims to draw special attention to it.
Table of Contents Disclaimers --------------------------------------------------------ii ESD Precautions --------------------------------------------------iii Unpacking ---------------------------------------------------------iv Safety Instructions ------------------------------------------------ v Chapter 1 Introduction-------------------------------------------- 1 1.1 General Description .........................................................1 1.2 Features ...............................................
2.4 CE Requirements .......................................................... 18 2.5 Dimensions of FPC-8057 ............................................. 19 Chapter 3 Windows CE.NET ------------------------------ 21 3.1 Introduction ............................................................... 21 3.2 Utilities ....................................................................... 22 3.2.1 Soft-Keyboard ......................................................... 22 3.2.2 System Settings ...............
FPC-8057 User’s Manual Chapter 1 Introduction 1.1 General Description The FPC-8057 series are fan-less and compact-size touch panel computers. It equips with 5.7” STN LCD display, Windows CE.NET and low power consumption CPU, Intel Xscale PXA255. Therefore, FPC8057 series are good cost-effective choices for operator interface applications. The FPC-8057 adopts most reliable and stable design.
FPC-8057 User’s Manual 1.2 Features z Fan-less and low power consumption CPU- Xscale PXA255 z 5.7” QVGA color STN LCD z Windows CE.NET supported and flash ROM on-board z Slim and compact size design z Suitable for reliable and vibration application – Fan less and CompactFlash card z NEMA 4 / IP65 compliant front panel z Support Compact Framework z Over-voltage power protection – fuse 1.3 Specifications z Construction: plastic molding housing z Display: 5.
FPC-8057 User’s Manual LCD Display z Display type: STN color LCD z Display size (diagonal): 5.7" z Max colors: 4096 z Resolution: 320 x 240 z Pixel pitch (HxV, mm): 0.36 x 0.
FPC-8057 User’s Manual z CE: Complies with EN50081-2 and EN50082-2 standards z Front panel meets NEMA4 / IP65 4 Introduction
FPC-8057 User’s Manual Chapter 2 Installation Instructions 2.1 Mounting Instructions 2.1.1 Location Considerations Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC output modules, contactors, starters and relays, and any other source of electrical interference are located away from the back of the unit. Particular note should be taken to the position of variable speed drives and switching power supplies.
FPC-8057 User’s Manual the unit is secured in the panel. Caution! Note: Do not over tighten mounting clamps! Specifications Note: To seal to NEMA-4 specifications, all supplied mounting clamps must be used and panel cannot flex more than 0.010”.
FPC-8057 User’s Manual 2.1.3 Environmental Considerations z The FPC-8057 are to be used indoors as built in displays. Make sure that the displays are installed correctly and that the operating limits are followed (See Specifications). z Do not operate the unit in areas subject to explosion hazards due to flammable gases, vapors or dusts. z The unit should not be installed where fast temperature variations and/or high humidity are present. This will cause condensation of water in the device.
FPC-8057 User’s Manual 2.2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit. Contact your local authorities to determine which codes apply.
FPC-8057 User’s Manual 2.2.1 Power Requirements The FPC-8057 can be powered by DC power only. The specified voltage range is +21 to 25 Volts DC. This Power insures compatibility with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 700mA. Fusing Requirements If the display does not come on within 2 seconds of power up, remove power.
FPC-8057 User’s Manual common paired with a hot or signal line. If wiring is to be exposed to lightning or surges, use appropriate surge suppression devices. Keep AC, high energy, and rapidly switching DC wiring separate from signal wires. Equip ungrounded DC supplies with a resistor and capacitor in parallel to earth ground. This provides a path for static and high frequency dissipation. Typical values to use are 1MOhm and 4700pF.
FPC-8057 User’s Manual FUSE Replacement: The fuse use on FPC-8057 is: BUSSMANN Fast Acting, Glass Tube Rating: 250VAC, 1A Size: 5x20mm Warning: Make sure the power off before replace the fuse. Do 1. not replace the fuse with a different rating fuse. 2. 2.2.2 Grounding Requirements Chassis ground must be used. DC ground is not directly coupled to Earth ground internally.
FPC-8057 User’s Manual 2.2.3 CE Requirements To make a FPC-8057 comply with EMC directives, and to reduce susceptibility to electrical interference, a separate #14 AWG ground wire should be taken to the chassis ground terminal of the power connector. This ground connection should be run directly to the central star earth connection point (as recommended in most Installation Instructions). 2.2.4 Safety Guidelines This section presents recommended installation practices, and procedures.
FPC-8057 User’s Manual Programming Considerations To conform to ICS Safety Recommendations, checks should be placed in the controller to ensure that all writable registers that control critical parts of plant or machinery have limit checks built into the program, with an out-oflimit safe shut down procedure to ensure safety of personnel. ICS 3-304.81 Safety Recommendations: Consideration should be given to the use of an emergency stop function, which is independent of the programmable controller.
FPC-8057 User’s Manual 2.3 Communications Connections There are several ports in the back of the case. Please take the following information for reference. 2.3.1 COM 1 [RS-232] Different cables are required for Cable Requirements Caution various devices. Restrict cable length to less than 50’ (15m) for RS-232 devices to avoid communications problems. Shielded cable must be used for long lengths or cables run in an electrically noisy environment.
FPC-8057 User’s Manual Pin assignment of the 9 Pin, Female, Pin Designations SUB-D, COM1 [RS-232] Port. Note: This port is not used for downloading or for printing functions.
FPC-8057 User’s Manual 2.3.2 COM2 [RS-232] & COM3 [RS-422/485] The 9 Pin, male, SUB-D, COM2 [RS-232] & COM3 [RS-422/485] Port on the back of the unit is the downloading port (PC Connector) and RS485/422 communications port for connecting to a device.
FPC-8057 User’s Manual 2.3.3 Dip Switch Pin1 Pin2 Mode OFF OFF Normal ON OFF Touch Screen Calibrate mode OFF ON Boot Loader mode PPin3, 4 unused z Touch Screen Calibrate mode: In this mode when you power on the FPC-8057, the screen will display a “+” sign at the center of the screen. Use a stylus or finger to push the center of the “+” until it moves. The “+” moves to upper-left, lower-left, lower-right and upperright corners. When all five “+” are done the “+” will disappear.
FPC-8057 User’s Manual z Boot Loader mode: Load new Windows CE.NET image file. If the 8057 FPC- already load the CE image with boot loader. Set the DIP SW2 ON then power ON into boot loader mode. Refer the load Win CE image document. 2.
FPC-8057 User’s Manual 2.
FPC-8057 User’s Manual 20 Installation Instructions
FPC-8057 User’s Manual Chapter 3 Windows CE.NET 3.1 Introduction The FPC-8057 series operator interface terminal is designed to serve on the Windows CE.NET platform. Designed from the ground up for the embedded marketplace, Windows CE.NET delivers a robust real-time operating system for rapidly building the next generation of smart mobile and small footprint devices. With a complete operating system feature set and end-to-end development environment, Windows CE.
FPC-8057 User’s Manual 3.2 Utilities There are several useful utilities built in the standard Windows CE.NET OS of FPC-8057: 3.2.1 Soft-Keyboard The FPC-8057 is dedicated to the small-sized operator interface. It is often inconvenient for users to attach a keyboard to such small machine. Thus, a software keyboard is embedded in the standard Windows CE.NET OS. Upon boot-up, a small keyboard icon will appear on the status bar. Tap this icon by the stylus to activate/hide this Soft-keyboard. 22 Windows CE.
FPC-8057 User’s Manual 3.2.2 System Settings FPC-8057 provides an integrated utility for users to make basic setting of the machine. Windows CE.
FPC-8057 User’s Manual
FPC-8057 User’s Manual disappear. The Touch Screen parameter will store at Flash Rom. Backlight “LCD Settings” page of the cecp provides the function to turn off the LCD backlight, and thus elongates the period of service. For example, if the user wants the backlight turned off automatically after 10 minutes when the device was no longer used. The user must select “10 minutes” in the put down box and then press “OK” button. Then the screen save function is enabled.
FPC-8057 User’s Manual MAC address The MAC address p age the block shows the network MAC address. S ave T ap the Save registry button, would save the reg istry data to the IPSM folder. Next time reboot the FPC-8057, Window s CE.NET system will use the stored registry data. 26 Windows CE.
Or in FPC-8057 \Windows folder click the “backupreg.exe” and it will save the registry data too. IPSM(Intel Persisten t Storage Manager) The IPSM serves as a small capacity hard disk. You can store your dat a and application in the Flash ROM via IPSM function to prevent nexpected loss of data as power failure. Whe u n power is shutdown and cold boot, the data in the Flash ROM area would be saved.
FPC-8057 User’s Manual 3.2.4 Startup After the system boot up, the startup execution function would a utomatically perform. This function is useful for control system to do the initialization p rocesses or some other programs. Step1: Create "startup" directory in in "\IPSM\". Step2: Copy executable files or Shortcut to "StartUp" directory, which is created in Step 1. An py alternative way to setup startup files is to make a shortcut and co it to "IPSM ecute a program with \StartUp".
FPC-8057 User’s Manual A .lnk file is a text file that contains the command line for the linke d target, which may be enclosed in double quotation marks, along with the length of that command line. Optionally, you can also pass parameters into the linked target. By default, a .lnk file uses the following format. [number of ASCII characters after pound sign]#[command line] [optional parameters] For example, to start M yApp.exe and pass two optional parameters into the application, a sample MyApp.
FPC-8057 User’s Manual To create a new Remote Desktop Connection 1. Open Remote Desktop Connection. 2. In Computer, type the computer nam e for your computer running Windows XP Professional that has Remote Desktop enabled and for which you have Remote Desktop permissions. Windows CE.
FPC-8057 User’s Manual 3. appears. Click Connect. The Log On to Windows dialog box 4. In the Log On to Windows dialog box, type your user name, password, and domain (if required), and then click OK. The Remote Desktop window will open and you will see the desk top settings, files, and programs that are on your office computer. Your office computer will remain locked.
FPC-8057 User’s Manual 3.3 FPC-8057 Networking 3.3.1 Networking via Ethernet The FPC-8057 is equipped with a 10Base-T Ethernet controller. To utilize it, change the device name when the FPC-8057 is first turned on. Step 1 Click “Start/Settings/Control ___ Panel” _____________________________________________ 2 Double click “Network and Dial-up Connections” 3 Find the default device name. Change it to a unique one depending on the plan of individual LANs.
server, please consult with MIS to get specific IP address. Click “Start/Settings/Control Panel”. Double click “Network and Dial-up Connections” and update ___ the IP address. _______________________________________ 6 Use the cecp utility “Save registry” to save this changed.
FPC-8057 User’s Manual 3 Connect the USB client port of the FPC-8057 and the USB host port of the host PC by the USB client to USB host ___ cable. _______________________________________________ 4 When the “Add New Hardware Wizard” asks for the driver, select the file D:\FPC-8057\USBdri __ ver\ wceusbsh.inf _____________________________________ 5 Follow the onscreen instructions to establish a partnership and synchronize your FPC8057with your desktop computer.
FPC-8057 User’s Manual 3.3.3 Web browser The FPC-8057 built-in Windows CE.NET OS includes Microsoft IE sample. It can be used to browse web pages on World Wide Web via LAN or dial-up connection. 34 Windows CE.
FPC-8057 User’s Manual 3.4 Application program development The FPC-8057 is bundled with built-in Windows CE.NET operating system and with Compact Framewrok. In real applications users need to execute various applications programs on it. However, unlike its other family the Windows CE.NET is a hardware-dependent operating system. That is to say, Windows CE.NET application programs are only portable in the source code level. Users must rebuild the runtime file for a different Windows CE.
FPC-8057 User’s Manual z Microsoft Windows® 2000 Professional SP2, Microsoft Window 2000 Server SP2, or Microsoft Windows XP Professional. z 96 MB (128 MB recommended) memory for Windows 2000 Professional or Windows XP Professional. 192 MB (256 MB recommended) memory for Windows 2000 Server. z CD-ROM drive required z VGA or higher-resolution monitor. A Super VGA (800 x 600 or larger) monitor is recommended. z Mouse or compatible pointing device. z 200 MB hard disk space. 36 Windows CE.
FPC-8057 User’s Manual 3.4.2 FPC-8057 SDK The FPC-8057 SDK provides developers with access to an extensive set of functions that are specific to the FPC-8057 hardware. Installing the FPC-8057 SDK Step 1. Download or from FPC-8057 SDK CD find the FPC-8057_SDK.msi file. Double click the file’s name start the Setup Wizard. 2 The installer will be prompted for acceptance of a license agreement.
FPC-8057 User’s Manual 3 38 When installation is complete the following message should appear: “Completing the FPC-8057 Setup Wizard”. The installer must press the “Finish” button in the install window to exit. Windows CE.
FPC-8057 User’s Manual Appendix A Example Program The FPC-8057 offers loop back test program for two comports. Please select the program D:\FPC-8057\Example\Serial Test. Serial port loop back test program Before running the program, you need to connect two comports of the FPC8057.
FPC-8057 User’s Manual This page does not contain any information.
FPC-8057 User’s Manual Appendix B How to Update WindowsCE image If you want to update new WindowsCE image to FPC-8057, you can follow the procedure. 1. Download newest version of WindowsCE image from Acnodes’ website. www.acnodes.com 2. Save new WindowsCE image into CompactFlash card and rename it to “nk.bin”. 3. Set the DIP switch as follows. 4. Power on the FPC-8057. Then, it updates FPC-8057 image and automatic reboot and into Windows CE.
FPC-8057 User’s Manual This page does not contain any information.
FPC-8057 User’s Manual Appendix C How to use development toolseMbedded C++4.0 The following procedure will show you how to use development tools-eMbedded C++4.0. 1. Before you start to develop the application program, you need to install following three S/W to Host PC. (1) USB driver in the driver CD. (2) eMbedded C++ 4.0 (3) Microsoft ActiveSync. software (4) SDK (Software Development kit) in the driver CD.
FPC-8057 User’s Manual 2. Plug synchronized cable which is in the package to the USB client port of the FPC-8057. 3. Run Microsoft ActiveSync. software.
FPC-8057 User’s Manual 4. Select “No” 5. Host PC synchronizes to FPC-8057. Click the item “Explore” and fine all folders in the FPC-8057.
FPC-8057 User’s Manual 6. If you plug the CompactFlash card in the FPC-8057. You can fine out the folder “StorgeCard” in FPC-8057. 7. Run eMbedded VC++4.0 in host PC..
FPC-8057 User’s Manual 8.
FPC-8057 User’s Manual 10. If you install FPC-8057’s SDK successfully, you can select FPC-8057 in the item. Then, click “Run” to compile your application program into “.exe” file. 11. The “.exe” file is being sent to the FPC-8057 sync. You can find it in FPC-8057.