4.9.2. Demo mode
When the demo mode is enabled, the AI of the pod is not used. All the process to detect and
classify the noise is replaced by a simple threshold detector. Therefore it is possible to simulate
a fake Gunshot and validate all the settings for the camera and pod angle with impulsive noise.
To simulate a gunshot, use some wood plate or metallic tools to have impulse noise. To have a
good localization process it is mandatory to have impulsive noise.
To enter on the Demo mode first set a Duration (min) in minutes and press the Apply button.
After this time, the pod will reboot to come back to ATD mode.
You can check that you are on the Demo mode on the Status page.
On the Status page, the pod mode changes to Demo. You also have the Threshold (dB) of the
demo mode, this value define in dB the sensitivity of the system during the demo. You can
change it on the Modes web page
The End of the Demo Mode (UTC) inform about the UTC time when the pod will reboot and
restart on the ATD mode.
Figure 24: Status web page for the ATD-300/ATD-301 demo mode