User's Manual

44
Brand of ACOEM
3.5.4 Run automatic diagnosis
This function gives directly the machine diagnosis after your measurement. This function needs that the machine is
created with NEST machine setup in “Automatic diagnosis” mode and that the instrument is equipped with the
“Diagnosis” option.
The diagnosis information is:
A pictogram giving the general status of the machine:
The machine is good
The machine is still acceptable
The machine is not acceptable
The rotation frequency and the number of measurement points used to compute the diagnosis
The comment concerning the general status
The list of detected defects with for each one:
o The type
o The severity:
Slight defect
Defect to be monitored
Defect to be corrected
o The confidence of the diagnosis:
*
suspected
**
likely
***
quite likely
**** certain
Functions of the screen:
Next: see directly the diagnosis of the next machine.
Previous: see directly the diagnosis of the previous machine.
Return: return back to measurement list screen.
Defect: see the details of the selected defect. The information on the defect is:
Defect type
Its severity (see above)
The confidence (see above)
The list of component or location of the machine where the defect is visible with for each one the
severity.
Functions of the “Defect detail” screen:
Next: go directly to the next defect.
Previous: go directly to the defect.
Return: return back to Diagnosis screen.
Notes: rotation speed is a very important parameter to get a good result. If the actual rotation speed is not correct,
it is possible to measure it again for variable speed machine or to adjust it using the stroboscope.
This adjustment is also possible with fixed speed machine. In this case the new rotation speed is used to
update the NEST initial setting.