User's Manual

26
4.2.2.
Spotface mounting
See Figure 26
This mounting mode is mainly dedicated to convex surfaces or to remove paint layers on a
machine.
Picture
Reference
Description
ACA1030000
Washer adapter for 1"1/4 spotface + M6 stud
Create a flat surface on the machine using a 1.25” [31.75 mm] spot facing tool with Step 1.
a drill bit for an M6 tap
Do not exceed 2 mm depth.
Thread the hole with M6 tap Step 2.
Screw M6 stud with a length of XXmm
Step 3.
CAUTION: The part of the stud inserted into the sensor can be up to 6 mm. A
bottoming stud may cause base-strain and also potentially damage electronics.
Thread the washer adapter on the stud. This washer is necessary to adapt the Step 4.
1.25 spotface depth and diameter to the sensor design.
Screw the sensor on the stud and tighten at 5 - 7 Nm [44 - 62 inch-lb] using the Step 5.
dedicated tube wrench and your handgrip.
NOTE: for a better contact a film of grease/oil can be applied between sensor and
mounting surface (note the oil/grease must be compatible with the temperature of
the measurement point).
CAUTION: If you use a 44 wrench or an adjustable wrench be careful to observe
the indicated torque range.
Fill in the installation report with sensor information (S/N, type, location, Step 6.
orientation)
Figure 27: spotfacing tool with drill bit
TRADUIRE