4.2.3.
Cementing pad mounting
This mounting mode is fast and easy.
Picture
Reference
Description
ACA1023000
M6 cementing pad - Ø35 mm [1.38 in]
Recommended adhesives:
HBM® X60: is a 2-component fast curing adhesive, consisting of a liquid component and
a powder.
LOCTITE® F246™: is a one component, toughened and high strength acrylic adhesive
system for structural bonding.
Remove coats of paint to get a clean metallic surface on the machine Step 1.
Remove grease from the surface Step 2.
Glue the cementing pad using HBM® X60 or LOCTITE® F246™ adhesive. Pin the Step 3.
pad to the surface.
WARNING: Refer to gluing safety datasheet and procedures before gluing and
always wear the prescribed protections.
Wait for the glue to dry Step 4.
Screw the sensor on the cementing pad and tighten at 5 - 7 Nm [44 - 62 inch-lb] Step 5.
using the dedicated tube wrench and your handgrip.
NOTE: for a better contact a film of grease/oil can be applied between sensor and
cementing pad (note the oil/grease must be compatible with the temperature of
the measurement point).
CAUTION: If you use a 44 wrench or an adjustable wrench be careful to observe
the indicated torque range.
Fill in the installation report with sensor information (S/N, type, location,
Step 6.
orientation)
Figure 28 : cementing pad mounting