4.2.5.
Temporary mount
Performing field test during a site survey may require a temporary mount. This allows testing
locations and orientations of the farthest sensors or those with doubts about their reception
because of their situation (metallic surroundings, casing, guards) to get the best coverage
possible.
A magnetic mount is the best solution in that specific case.
Screw the sensor on the magnetic base using appropriated stud or bolt (M6). Step 1.
Place the system on the location to test Step 2.
NOTE: An adapter stud may be required depending on the design of the magnetic base to
allow M6 mount.
Table 11: magnetic mounts references
Brand
Reference
Adapter stud
Pull strength
Max temp.
CTC
MH114-3A +
MH108-5B
1/4-28 to M6-1
23kg [50lbs]
80°C [176°F]
OneProd
ACA To be defined
N/A
23kg [50lbs]
80°C [176°F]
Figure 30 : multi-purpose magnetic base