User's Manual

38
1. USAGE
1.1. POWER UP THE SENSOR AND EXPANDER
To power the Eagle Field Device for the first time, unscrew the battery and remove the
protective tape on the battery's connectors. Then screw the battery fully
1.1.1.
Sleep mode
After power-up the Eagle field device will attempt to join the ISA100.11a network every 5
minutes while entering in an ultra-low power state between the join attempts. After 30
minutes the join attempt period will increase to 15 minutes for the subsequent 24 hours
followed by one join attempt per hour.
To exit sleep mode unscrew and screw the battery fully (off/on).
2. EAGLE EMBEDDED PROCESSING
2.1. PARAMETERS
2.1.1.
Overall velocity
Table 13: overall velocity parameter settings for Eagle sensor
Paramètre mesuré
Vitesse vibratoire
Unité résultat
mm/s
inch/s
Référence dB
Not used
Type entrée
Accéléromètre
Unité entrée
g
Sensibilité (mV/unité entrée)
Not used
Pleine échelle (unité param)
Not used
Autorange
YES (fixed)
Intégration
1 intégration
Surveillance temps réel
Not used
Constante de temps
Not used
Filtre passe haut
2 Hz
10 Hz
Filtre passe bas
sans
1 kHz
Détection
RMS
Durée
5s (fixed)
Moyennage
Average (fixed)
2.1.2.
Overall acceleration
Table 14: overall acceleration parameter settings for Eagle sensor
Paramètre mesuré
Accélération
Unité résultat
g
Référence dB
Not used
Type entrée
Accéléromètre
Unité entrée
g
Sensibilité (mV/unité entrée)
Not used
Pleine échelle (unité param)
Not used
Autorange
Oui
Intégration
0 intégration
Surveillance temps réel
Not used
Constante de temps