5.6. DISMANTLING / RECYCLING
The disposal or recycling of batteries must comply with the applicable directives of
your country.
The disposal or recycling of the Eagle devices must be in accordance with the valid
directive on waste electrical and electronic equipment (WEEE) (2012/19/EC).
Gateway, sensor, expander and their accessories should be recycled as electronic
products including a battery.
Gateway, sensor, expander and their accessories should not be burnt or thrown into
fire.
Gateway, sensor, expander and their accessories should not be disposed in a dump.
6. ANNEX: SUMMARY OF MARKING MEANING FOR HAZARDOUS AREAS
The information below is general and should consulted beings as such. Read carefully the
labeling of each product.
Product intended for explosive atmospheres
I / II Applications
I = Mining industry applications
II = Surface industry applications
1 / 3 Explosive zones for surface industry
1 = intended for Zone 0 (gas) with a permanent explosive atmosphere. EPL level Ga.
3 = intended for Zone 2 (gas) where an explosive atmosphere may only appear accidentally, in
case of malfunction of the installation. EPL level Gc.
M1 Explosive zone for mining industry Zone 0 (gas) with a permanent explosive atmosphere.
G Gas atmosphere
Ex Protection against explosions
ia / ic Protection modes intended to prevent explosion
ia for flammable material always present or for long periods Zone 0
ic for Irregular / short term presence of gas (abnormal) Zone 2
IIC Devices intended to operate in presence of the most explosive substances: hydrogen, acetylene,
ethyl nitrate …
IIC product is automatically suitable for groups IIA and IIB.
Ga / Gc Equipment protection level
EPL A = for permanent or frequent presence of gaz (zone 0)
EPL C = for Irregular / short term / abnormal presence of gas (zone 2)
T4 Gas surface temperature pour an ambiante temperature Ta.
< 135°C [275°F] pour -xx°C<Ta and +xx°C
LCIE ATEX certificate number provided by notified body (LCIE)
IECEx Certificate of conformity to IEC standards (Certification scheme IECEX)
X Indication of particular condition(s) of use