User's Manual

1212
Fig. 3-2 Basic screen
b) Operating values and alarm messages area.
Any two operating values selected in the AMP MEASURE menu (S. 5-1) will be shown here.
The alarm messages (either WARNING or SOFT FAULT) appear on yellow background on the same
area and are ashing frequently in order to attract the operator’s attention (Fig. 4-1).
The WARNING messages appear only temporarily (for about three seconds), afterwards the indication
of the operating values is restored automatically (S. 4-4(a).
The SOFT FAULT messages appear in the same eld but they remain on the screen until the AUTO
OPERATE time is elapsed (S.4-1(c)) or until the operator pushes any button, then the operating values
indication is restored too.
c) Working mode indicator - OPR, STB or AUTO OPER (S. 4-1).
d) RX/TX indicator - reads the request for transmit (KEY-IN input). The RX indication is green and
the TX is red. The indicator will ash frequently if switch over is impossible.
e) Forward power bargraph and digital readout. Displays the power fed into the antenna.
f) Reected power bargraph and readout. Entering the red zone is not allowed.
g) PA transistor temperature bargraph and readout. Entering the red zone is not allowed.
h) CAT interface information. When CAT is deactivated, this eld is shaded.
i) REMOTE CONTROL information eld–ashing represents RS232 port dataow.