Service manual

61
Manual Operation of Magnetrons #1
Screen This screen will allow operation of
Magnetron #1 and show the
number of amps being drawn.
Press this pad to go to the
next Service Mode Test
Press this pad to go to the
previous Service Mode Test
This pad will turn the magnetron on.
RANGE: Under normal operation, each
mag’s amp draw should be 5 – 12 amps.
Manual Operation of Magnetron #2
Screen This screen will allow operation of
Magnetron #2 and show the number of
amps being drawn.
2
3
SERVICE MODE
Magnetron 1
9 AMPS
02
SE
R
VI
C
E
MO
D
E
Magnetron 1
9 AMPS
02
number
number
previous
SERVICE MODE
Magnetron 2
9 AMPS
03
SE
R
VI
C
E
MO
D
E
Magnetron 2
9 AMPS
03
This pad will turn the magnetron off.
Press this pad to go to the
next Service Mode Test
Press this pad to go to the
previous Service Mode Test
This pad will turn the magnetron on.
RANGE: Under normal operation, each
mag’s amp draw should be 5 – 12 amps.
amps
previous
This pad will turn the magnetron off.
Press this pad repeatedly
to exit Service Mode
Press this pad repeatedly
to exit Service Mode.