Service manual

63
Convection Fan – Low Speed
Screen This screen will allow operation of the
convection fan at a low speed and show the
number of amps being drawn.
7
Press this pad to go to the
next Service Mode Test
Press this pad to go to the
previous Service Mode Test
This pad will turn the fan on.
RANGE: Under normal operation, the
amp draw is too low to read.
number
previous
This pad will turn the fan off.
SERVICE MODE
Convection Fan
Low
0.0 AMPS
06
SE
R
VI
C
E
MO
D
E
Convection Fan
Low
0.0 AMPS
06
Convection Fan – High Speed
Screen This screen will allow operation of the
convection fan at a high speed and show the
number of amps being drawn.
8
Press this pad to go to the
next Service Mode Test
Press this pad to go to the
previous Service Mode Test
This pad will turn the fan on.
RANGE: Under normal operation, the
amp draw should be 0.6 - 2.6 amps.
(It may not read amps)
number
previous
This pad will turn the fan off.
SERVICE MODE
Convection Fan
High
0.0 AMPS
07
SE
R
VI
C
E
MO
D
E
Convection Fan
High
0.0 AMPS
07
Press this pad repeatedly