Service manual

9:
1
3
2
4
6
5
7 8
0
9
abc def
jklghi
. ’ - #
mno
tuvpqrs wxyz
& /
SERVICE MODE
MAGNETRON 1
0 AMPS
Yes
SERVICE TEST
1. Press Off Pad Repeatedly
Until Press to Off Icon Appears
2. Press Hidden Pad
3. Press Pads 1-3-5-7-9
No
PRESS START
No
Inoperative Main Board
COOLING FANS
TURNS ON
Yes
No
1. Inoperative Power Relay
2. Inoperative Primary Switch
3. Inoperative Secondary Switch
4. Fuse (F3)
5. Fuse (F4)
7. Inoperative Main Board
8. Inoperative Capacitor
9. Inoperative Diode
10. Inoperative H.V. Transformer
MAGNETRON #1: 5-12 AMPS
SERVICE MODE
OVEN INFORMATION
DISPLAY VERSION: 11
MAIN VER: 73
EE 3
DOOR CYCLES 1149
TUBE HRS: 2156
PRESS ENTER
Yes
MICROWAVE CONDITION
Hidden Pad
No
Yes
(NORMAL DISPLAY)
(NORMAL DISPLAY)
6. Inoperative Triac
See component test procedures section
for testing procedures and results.
See component test procedures section
for testing procedures and results.
See component test procedures section
for testing procedures and results.
See component test procedures section
for testing procedures and results.
01
SE
R
VI
C
E
MO
D
E
MAGNETRON 1
0 AMPS
SE
R
VI
C
E
MO
D
E
OVEN INFORMATION
DISPLAY VERSION: 11
MAIN VER: 73
EE 3
DOOR CYCLES 1149
TUBE HRS: 2156
01
02
Repeat test for
Service Mode 03
Magnetron 2
!"#$%&'("")*+,-./01223-4-./01225