Service manual

18
Display Diagnostics
ERROR CODES:
DISPLAY
DESCRIPTION
CORRECTIVE ACTION
B0 Touch Panel Replace Touch Panel
B1 Touch Panel Replace Touch Panel
C-0
Temp Sensor (RTD) (open)
Replace Temp Sensor
C-1
Temp Sensor (RTD) (shorted)
C-2
Temp Sensor (RTD)
(out of range)
D-0 Thermocouple (RTD) (open)
D-1
Thermocouple (RTD) (shorted)
D-2
Thermocouple (RTD)
(out of range)
G-0 Oven Exceeded Max. Temp. Unplug / Plug oven in
G-2
G-2
Magnetron TCO
Cooling Motor
Perform service test
Perform service test
H-0 Signal Missing Plug disconnected from J1 on main
board
H-1 Main Board Set Point Incorrect. Unplug / Plug oven in
H-2 Main Board Replace main board
H-3 Main Board Replace main board
NOTE: While in the service test the error history can be cleared
by pressing and holding Pad One. (Page 27)
Replace Temp Sensor
Replace Temp Sensor
Replace Thermocouple
Replace Thermocouple
Replace Thermocouple