630140_1 XFIRE_1200_GB_Manual_R‐emotion X-FIRE 1200 ® Designer Balanced Flue Fires INSTALLATION & USERS INSTRUCTIONS PRODUCT CODES XT-LIM X-FIRE 1200 Limestone XT-GRA X-FIRE 1200 Granite XT-TRA X-FIRE 1200 Travertine LEAVE WITH THE USER Acquisitions of London 24 Holmes Road London NW5 3AB England Tel: 0044 (0)207 482 2949 Email: sales@acquisitions.co.
630140_1 XFIRE_1200_GB_Manual_R‐emotion INTELLECTUAL PROPERTY Acquisitions XFIRES is a Registered Trade Mark Components of this product are protected under GB Patent no: GB2429186 Similar applications are pending in Europe, USA, Canada, China, Hong Kong, Australia and New Zealand.
630140_1 XFIRE_1200_GB_Manual_R‐emotion Note: THERE ARE A FEW THINGS TO CONSIDER BEFORE INSTALLATION • • • • • • • Cavity Dimensions and Clearances MUST be installed 100mm minimum off the floor or nearest horizontal surface. Coupling of flue to fire Coupling of gas lines to fire Fixing the fire to cavity Gas pipe placement to the front left of the cavity.
630140_1 XFIRE_1200_GB_Manual_R‐emotion Contents: 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 21.0 22.0 23.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 1.0 Product Description: The XFIRE 1200 decorative gas fire is designed to be built into a cavity. The appliance is flued via Simpson Duravent Direct Vent Pro 5” x 8” Flue, available only from SpecFlue. Users may control their fire with the Radio Frequency (RF) remote. The glass on the front of the appliance is considered a working surface, and as such, care should be taken not to touch this while the appliance is running as it will get hot. 1.
30140_1 XFIRE_1200_GB_Manual_R‐emotion 2.0 Creating the Cavity: The dimensioned drawing below shows the size of opening that must be created to fit the XFIRE 1200. The wall directly above the fire should be finished / clad / lined after the fire has been installed, unless there is an access hatch or the chase is open to the ceiling cavity, which allows the flue to be installed after the wall has been lined. Note: It is not necessary to line or vent the cavity, and it may be constructed with timber.
630140_1 XFIRE_1200_GB_Manual_R‐emotion Flush TV with small mantle Recessed TV Mantle above fire Protruding fire 50 min 50 min 100 min 50 min 50 min 50 min 50 min 50 min 100 min Mantle Mantle 500 min 500 min 500 min 500 min The material that the wall and mantle are made from will also affect the operating temperature of the TV so it is the customers responsibility to satisfy themselves that their TV mounting and mantle design will not exceed the listed maximum operating temperature of their e
630140_1 XFIRE_1200_GB_Manual_R‐emotion 5.2 Non-Combustible Mantle Clearances: If the entire installation (mantle, wall and cavity) is constructed from non-combustible materials, the clearances to mantles may be as shown in the shaded area. 6.0 Corner Installations: If a cavity is to be created in a corner, the following drawing gives the minimum sizes. 7.0 Laying Gas Pipe: Gas pipe should be sized as per the requirements of BS 6896.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 8.0 Connecting the Gas Pipe to the Fireplace: Before the gas pipe can be connected to the fireplace, the Inlet Connection fitting and the Inlet Test Point fitting must first be fitted to the appliance pressure regulator. 8.1 The fittings supplied with the fire need to be fitted to the pressure governor. A suitable joint sealant and/or thread tape needs to be used on these unions.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 10.0 Fixing the Fire to the base and wall: It is a requirement that this fire be securely fastened to the wall and base. Once the fire has been pushed back into the correct position, use wood screws (or other suitable fasteners) to fix the fire to the cavity through each of the four holes in the corners, as shown in the diagram to the right. Note: It may be necessary to use washers on the fasteners to securely fasten the fire to the wall.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.0 Installing the Flue System: Ensure all flue components are Simpson Duravent Direct Vent Pro 5” x 8,” no other flue types may be used. This flue is available on 24 hour delivery only from SpecFlue UK FreeFone 0800 9020220 International +44 1787 880333 Note: Consult section 12.13 of this installation manual to ensure correct length of flue is calculated.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.5 Vertical Only Flue Diagram: Use this diagram to determine what percentage of flue restriction is required to ensure safe and correct operation of the XFIRE1200 balanced flue decorative gas fireplace.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.6 Horizontally Terminating Flue Diagram: Use this diagram to determine what percentage of flue restriction is required to ensure safe and correct operation of the XFIRE1200 balanced flue decorative gas fireplace.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.7 Vertically Terminating flue with a Horizontal Offset: Use this diagram to determine what percentage of flue restriction is required to ensure safe and correct operation of the XFIRE1200 balanced flue decorative gas fireplace.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.8 Standard Flueing Configurations: The following flue components are available from your SpecFlue, UK FreeFone 0800 9020220, International +44 1787 880333 in kitset form.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.9 Locating the Flue Terminal: The flue terminal must be located using the information given in the following excerpts from BS 5440-1.
630140_1 XFIRE_1200_GB_Manual_R‐emotion
630140_1 XFIRE_1200_GB_Manual_R‐emotion
630140_1 XFIRE_1200_GB_Manual_R‐emotion Figure C.2 Minimum dimensions of room-sealed chimney outlet positions (refer to Figure C.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.11 Sealing ‘through roof’ and ‘through wall’ penetrations: For ‘through roof’ penetrations, use a Master Flash flashing or equivalent to create a weather-tight seal between the flue and the roof cladding. For ‘through wall’ penetrations, this will require the use of a Wall Thimble. The Wall Thimble will ensure you have suitable clearance from combustibles as well as sealing the penetration.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 12.13 Points to note when planning the Installation of the Escea DV flue: - This flue system cannot be cut to length. Correct lengths must be selected for each installation. For a full list of available flue lengths, contact your Escea retailer. - The listed length of the flue pipe is not the installed length. 1 ½” (38mm) needs to be subtracted for each join to determine the installed length of each piece of flue pipe. E.g. 48” length has installed length of 45”.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 13.0 Fitting the Flue Restrictor: If your flueing configuration requires that you fit a flue restrictor (see graphs in section 12.5, 12.6 & 12.7 of this manual to find out if your configuration requires a flue restrictor), follow the instructions below.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 14.0 Converting to G31 Propane Gas: Where a conversion to propane gas is needed, the following steps should be followed 14.1 First you need to remove the burner by removing the screw holding it in place on the left hand side of the firebox (Fig. 1). Then remove the 1.9mm burner jet (Fig. 2) and replace it with the 1.3mm jet supplied in the kit. Now remove the gas pipe fitting under the pilot (Fig. 3) and remove the No.48 pilot Jet (Fig.
630140_1 XFIRE_1200_GB_Manual_R‐emotion Finally, put the sticker supplied in the conversion kit in onto the dataplate of the ST900 in the position shown. The sticker must be signed and dated by the installer who has converted the fire.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 15.0 Placing the Fuel Bed Media: Your XFIRE 1200 Gas fire will be supplied with a Fuel Bed kit. Follow the instructions below for the Fuel Bed kit that applies to you. 15.1 Driftwood Fuel Bed: First scatter one layer of the supplied white stones evenly across the base of the firebox, ensuring there are no stones or driftwood pieces inside the pilot flame surround guard. Arrange the supplied driftwood pieces exactly as shown in the diagram and photo below.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 16.0 Checking Operating Pressure: WARNING: The regulator that is supplied with the fire MUST NOT BE REMOVED. Removal of the regulator, or replacing it with one not intended for use with an Escea fire, will void the limited appliance warranty. Check the operating pressure at the regulator located at the front LH corner of the appliance. This is best done before the facia panels have been fitted to avoid facia damage.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 17.0 Covering up the fire: Before the wall surrounding the ST900 is lined, the fire must be covered up and sealed to prevent plaster board and plaster dust from getting into the fire. It is recommended that the packaging supplied with the fire is used to achieve this. 18.
630140_1 XFIRE_1200_GB_Manual_R‐emotion The stone frame uses these four hooks for attaching to the fire. Do this by lining up the facia hooks with the receptacles on the sides of the fire. Lift the facia so that the hooks are above the receptacles, and let it drop down into position until it is secure and free from movement. Remove all protective plastic and packaging material before operating the fire. Care should be taken when handling the facia.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 18.3 Cleaning: Before carrying out any of the following operations, ensure the the appliance is OFF and completely cold. Glass Panel: Remove as described in section 11. This can be cleaned inside and out with proprietary window-glass cleaner, or proprietary ceramic hob cleaner if badly stained. Test on a small area first. Do not allow the glass to become badly stained as this will be difficult to remove.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 19.0 Operating Instructions: The XFIRE 1200 remote control allows you to turn ON and OFF the fire, control the flame height in the Manual mode, or control the room temperature in the Thermostat mode. The remote has a maximum range of approximately 10 meters, and because the remote works by radio frequency, it does not need to be aimed at the XFIRE 1200 for it to operate.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 19.4 Switching off the XFIRE 1200: To turn off the fire, push the OFF button, to shut down the gas flow to the fire and switch it off. The OFF display will now appear in the display. 19.5 Setting the control mode for the fireplace: There are three different modes for controlling the appliance: > Manual > Automatic > Program Automatic mode allows you to set a temperature, while in manual mode the flame level may be set to HIGH, MEDIUM, LOW & PILOT.
63014 40_1 XFIRE_1 1200_GB_Maanual_R‐emo otion > Prog gram mode e: By defa ault the pro ogram mod de is not enabled. To o enable prrogram mo ode, enter configuratiion mode by b pressing g and hold ding the OF FF button for f 40 seco onds, seleccting “Prog gramming” and selectin ng “yes” (F For more in nformation on configu uration mode see secction 19.9)). There are a two typ pes of prog gram mode e: a Daily mode m and a Weekly m mode. In th he daily mode, every day uses the same s program.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 19.5 Changing the display from Celsius to Fahrenheit: Go into Menu → Adjust menu → Unit. Press middle button and then left button for changing units. 19.6 To Lock / Unlock the remote control buttons: Go into Menu → Lock. Press middle button and then left button for locking the remote. To unlock press left button and then middle button. 19.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 19.9 Pairing the Remote to the Control Unit: Install batteries to the battery pack and after a while the valve motor will start moving (if not wait one minute from the time of installing batteries). Once the valve has finished moving, press the OFF button on the remote control for 40 seconds. During this time the screen may go blank, this is normal.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 19.10 Initial configuration: To enter the configuration menu, press the OFF button on the remote control for 40 seconds. During this time the screen may go blank, this is normal. After 40 seconds, the configuration menu appears. It is possible to configure the appliance with the following options: • • Thermostat: This option enables or disables the auto thermostat mode. To enable it, select Yes. To disable it select No.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 20.0 Sounds and Smells: Note: Each time the fire is lit from cold, the glass may mist with condensation. This is normal and the condensation will disappear within a few minutes once the glass heats up. 20.1 Sounds: It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various types of materials used within your appliance. Listed below are some examples.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 21.0 Annual Service Check: The Fireplace should be serviced annually to ensure it continues to operate in a safe manner. This annual service check should involve the following • Replace thermocouple • Check glass assembly gasket • Clean pilot and main burner jets • Paint firebox [if required] • Inspect flue system [if possible] • General clean and inspection 22.
630140_1 XFIRE_1200_GB_Manual_R‐emotion 24.0 WARRANTY TERMS & CONDITIONS: This warranty does not affect your statutory rights.
630140_1 XFIRE_1200_GB _Service_R‐emotion
630140_1 XFIRE_1200_GB _Service_R‐emotion
630140_1 XFIRE_1200_GB _Service_R‐emotion 15.0 Troubleshooting Use the following troubleshooting chart to diagnose and fault‐find operational issues with XFIRE 1200 decorative gas fireplaces.
630140_1 XFIRE_1200_GB _Service_R‐emotion 13.0 Re‐establish Power and Gas Connections With all applicable service work completed and the fire fully assembled again the gas can be re‐established and the batteries replaced. Check gas inlet pressure against data plate at pressure test point using a manometer. Adjust gas pressure to specifications. Remove the manometer and replace the test point screw. Leak test all test points and gas system joins/unions.
8.0 630140_1 XFIRE_1200_GB _Service_R‐emotion Clean Thermocouple: With the Pilot Cover removed you now have access to clean the thermocouple. Do this by wiping it down with a rag or other appropriate cleaning tools in order to remove any soot from the surface. 9.0 Paint Firebox [if required]: If there are any scrapes or damage to the paint on the inside of the firebox you may wish to touch up the paint. To do this, use a suitable high temperature matt black paint.
6.0 630140_1 XFIRE_1200_GB _Service_R‐emotion Once the control unit cover has been removed the main gas connection, Valve to Pilot tube, and Valve to Burner tubes should be disconnected. Push the thermocouple down from inside the firebox to disconnect from pilot assembly. Once the two screws pictured above are removed the tray is free to be lifted (ensuring that all wiring is clear from sheet metal) up 15mm to clear the metal edge and pulled towards you.
4.0 630140_1 XFIRE_1200_GB _Service_R‐emotion Remove Firebox Contents: Ensure the firebox contents have cooled down completely before attempting to touch or remove any part. First remove all fuel bed media (Driftwood and white stones or Coals) and place them carefully to the side somewhere they will not be damaged.
1.0 630140_1 XFIRE_1200_GB _Service_R‐emotion Isolate Power and Gas Supply: Before any service and maintenance work is done on the fire, the gas supply must be isolated or shut off. Gas can be isolated by either turning the gas off at the cylinders, at the meter or at the appliance isolation valve. Power can be isolated by removing the batteries from the battery pack. 2.0 Remove the Facia: Ensure the facia has cooled before attempting to remove it. The facia attaches to the fire by four hooks.
630140_1 XFIRE_1200_GB _Service_R‐emotion Contents: DIS‐ASSEMBLY SERVICE RE‐ASSEMBLY ‐ Isolate power and gas supply Check glass assembly ‐ Remove Control Tray [if required] ‐ Remove firebox contents ‐ Remove glass assembly ‐ Remove facia ‐ ‐ ‐ ‐ ‐ ‐ ‐ Re‐assemble ‐ General clean and inspection ‐ Inspect flue system [if possible] ‐ Paint firebox [if required] ‐ Clean burner thermocouple ‐ Clean pilot and main burner jet ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ Replace facia ‐ ‐ Re‐establish gas an
630140_1 XFIRE_1200_GB _Service_R‐emotion X-FIRE 1200 ® Designer Balanced Flue Fires SERVICE GUIDE Important • • • It is recommended that this appliance be serviced every 12 months Any service operation should be carried out only by a suitably qualified and trained person Gas supply MUST be isolated before any service operation is carried out on this appliance. DISTRIBUTED BY Acquisitions of London 24-26 Holmes Road London NW5 3AB Tel: 24 hours 0044 (0)207 482 2949 Email: sales@acquisitions.co.