25-69-01
Page 35 of 44
JUN 27/12
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
DGL-1, DONGLE (453-4010)
Figure 7. Molex Power and Ground Wires
(9) Connect the ground to the black, un-terminated wire.
NOTE
: Refer to Raychem for specific instructions on the splice use. Alternate splices may be
used if installed in accordance with FAA AC 43.13.1A, Section 445, Splices in
Electrical Wire.
(a) A Raychem solder sleeve splice (Raychem P/N D-1744-01) is provided for this
connection.
(b) For installations of a ELT/Dongle, splice the black wire to an aircraft ground point near
the ELT. See "Figure 8. Dongle Wiring Diagram".
NOTE
: Pin 11 will not be available for remote switch grounding with the Dongle/ELT
installation. Slice a ground for the remote switch .
(c) For Dongle installations on previously installed ELT, ground the un-terminated ground
wire from the remote switch as described above.
(10) Feed the black circular connector through the rectangular hole in the ELT end cap.
(11) Connect the black circular connector to the plug on the Dongle.
RED
TO 28 VDC
BLACK
TO GROUND