Instruction Manual

Artex Products / ACR Electronics, Inc. 570-0023 Rev. G
Page 21 of 33
9. 453-1101 MODULE INTERFACE AND 452-6505 BUZZER WIRING
9.1 Instructions
9.1.1 Follow the appropriate wiring diagram in Section 5, depending if the aircraft is metal or
composite.
Connect RED wire to Horn Power connection
Connect BLACK wire to A/C Ground
Cap & stow BLUE wire
9.1.2 Mount the buzzer according to the instructions highlighted in the ME406 series ELT
manuals.
NOTE: Allow enough slack to prevent tensile load on the wires leading from the module
interface and the buzzer. Depending on the location of the buzzer, additional wires can
be strung between the buzzer and the module interface.
10. REMOTE SWITCH CELL REPLACEMENT
131-0001 CELL WARNING:
DO NOT RECHARGE, SHORT-CIRCUIT, DISASSEMBLE, DEFORM,
HEAT OR PLACE NEAR A DIRECT FLAME
10.1 Cell Shelf Life
10.1.1 The shelf life of the cell is 5 years. The cell is available through ACR Electronics, Inc.
under part number 131-0001.
10.1.2 The Lithium content of the cell is less than 0.15 Gram.