Ensure your GPS has acquired a valid position. Momentarily lift the "ON/OFF"
switch to the self-test position and stand-by. The beacon will go through it’s self
test routine and approx. 2 seconds after the LED turns green the unit will beep
once and the Yellow LED will flash to indicate that valid GPS data has been
transferred into your UNIT. Repeat step 3.2.2 if no conformation.
The beacon will automatically up load new GPS position every 30 minutes if you
leave it connected to your GPS receiver.
When you activate self-test the beacon will start to look for new GPS data and
update accordingly, if no new data is present or cable is disconnected the original
data will still stay in memory.
Once data has been loaded into your UNIT it will remain there until the unit is
activated to the "ON" mode.
EXTERNAL GPS I/R CABLE
FIGURE 8
3.2.4 Default data:
Default data is when there is no GPS data in the unit. The beacon reverts to
default data once the unit has been activated and then shutoff. The unit will
function normally without GPS data.
4.0 MAINTENANCE