Specifications
39
6.1.2
MX51X Display Unit
The display unit can be installed as bracket mounted or flush mounted in a panel. Installation shall be
near the conning position.
When selecting a mounting location for the Display Unit the following guidelines apply:
1. Do not mount the display unit where it can be directly exposed to seawater as corrosion
then may appear and cause leakage.
2. The unit must not be mounted near exhaust pipes and vents.
3. Even though the transponder is a robust unit, it is advised that it should be mounted were
shock and vibration are minimal.
4. Unit shall not be located near electromagnetic field generating equipment
5. Leave sufficient space at the back for connection to necessary cables.
6. Do not mount transponder unit too close to a magnetic compass:
Compass safe distance:
Standard Compass:
30 cm
Steering Compass:
14 cm
6.1.2.1 Bracket Mounting
Figure 6.2 Bracket mounted MX51x display unit and bracket mount
When display unit is mounted overhead, it might be necessary to adjust Contrast. This can be done by using
the procedure below:
1. Press the CFG key.
2. Scroll down to “Lighting” menu.
3. Press the EDIT key.
4. Change the contrast by using the left or right arrow keys.
5. Press the EDIT key to exit.
For detailed mechanical drawings, see chapter 12 Outline Drawings.