6.3.6 Power Connection
Table showing connection of main and backup power - See also Figure 8-10
Connection
Function
P1
GND (Chassis)
P2
MAIN 0 V
P3
MAIN 12 - 24 VDC
P4
GND (Chassis)
P5
BACKUP 0 V
P6
BACKUP 12 – 24 VDC
Allowed voltage levels of the power supply to be connected with the transponder:
Minimum = 10.8 Volt and Maximum = 31.2 Volt
Recommended cable diameter: 2.5 – 4 mm
2
6.3.7
Sensor Connections
Sensors like GPS, Gyro, Speed log etc… may be connected to the 3 different sensor inputs in the
MX535B Transponder unit.
Figure 6.12 Sensor Terminals
Recommended cable diameter: 0.25 - 2.5 mm
2
#
In/
Out
Typ
e
Usage
N
ame
1
In
IEC61162-1
(RS422)
Sensor 1
RD1-B(+)
2
RD1 -GND (Iso Gnd)
3
In RD1-A(-)