Specifications
70
035 No valid ROT
information
External rotation sensor The Transponder continues operation using default
data.
Check wiring and external sensor.
Check baud rate settings.
Table 2: Integrity alarm conditions signaled using ALR sentence formatter.
*The Rx Alarm is triggered if one of the internal frequency generators is out of lock, making the receiver unable to function at
the correct frequency.
Any of the AIS Alarms can be deselected using the procedure below:
1. Press the CFG key.
2. Scroll to ALARMS menu.
3. Press the EDIT key.
4. Scroll down to the bottom of the alarm list where all the AIS alarms are located.
5. Press the ENT key to change the value to OFF (to deactivate) or ON (to activate).
6. Press the EDIT key to exit.
8.2.4 Alarm Relay Output
The Alarm relay is a normally open earth free relay contact, provided as an independent and simple method
for triggering an external alarm. The alarm relay is deactivated upon acknowledgment of an alarm, either
internally on the display unit, or by an externally provided ACK sentence. If the Transponder power is lost,
and the Alarm relay has power, the alarm will be triggered. In this case, the only way to deactivate the Alarm
is to power the Transponder unit or disconnect the power source of the Alarm relay.
Figure 8.2 Typical Alarm connection