Specifications
Y1-03-0141F  9 
Figure 6- URP-102 Point Pad™ 
Surface Mount Case with gasket and Flush Mount Case with gasket 
SECTION 6- URC-102 Master Controller 
Mounting 
The  Master  Controller can  be mounted  in any  position near  the searchlight that  is 
protected from the weather. Check in advance that the coax cable from the Point Pad™ 
and the wiring harness from the  searchlight can be routed to this location.  Mount the 
Master Controller with the wires and coax facing down. Use an appropriate fastener for 
your mounting location. Use a sealant in fastener holes to prevent moisture intrusion. 
General wiring scheme 
The RCL-50B  has a unique  wiring scheme. Special attention  must be paid to  the 
following  chart.  The  Master  Controller  is  supplied  with  an  in-line  fuse-holder  on  the 
orange  power lead.  Use  only  15  amp  fuses  in  this  fuse-holder.  See  Figure  9  for  the 
master controller wiring diagram. 
WARNING: Failure to follow this arrangement may damage components. 
Master 
Controller Wire 
Searchlight 
Cable Wire 
Power Source Lead 
Function 
Orange 
+12 VDC or +24 
VDC** 
Power 
Blue 
Ground 
Ground 
Yellow 
Yellow 
Lamp Power 
Green 
Green 
Lamp Ground 
Red 
Red 
Up 
White 
White 
Down 
Black 
Black 
Right 
Brown 
Brown 
Left 
Table 1 