Specifications
Y1-03-0141F  11 
The URC-102 Master Controller has the unique XRCiZ™ feature. The XRCiZ™ feature 
routinely  operates  all  moving  parts  in  the  searchlight  to  keep  the  motors  and  drive 
mechanism freely running. Once activated, and every 30 days thereafter, the XRCiZ™ 
feature wakes up and operates the searchlight. The searchlight will rotate 360 in both 
directions and the parabolic reflectors will move to the full up and down positions. This 
feature keeps the searchlight in peak working order when not in service for long periods 
of time. 
To  activate  the  XRCiZ™  feature,  press and  hold  the Point  Pad™ on/off  button for 
greater than 5 seconds. The green LED on the URC-102 Point Pad™ indicates that the 
XRCiZ™ feature is enabled. While enabled, the XRCiZ™ feature can be started outside 
of its  30-day  cycle by pressing and holding  the  speed  button  on  the  Point Pad™  for 
greater than 5 seconds. 
While the XRCiZ™ feature is operating the searchlight, pressing any Point Pad™ button 
will stop the current cycle and leave the searchlight to follow any additional commands.  
To deactivate the XRCiZ™  feature, press  and  hold  the  Point  Pad™  on/off  button  for 
greater than 5 seconds. The red LED on the URC-102 Point Pad™ indicates  that  the 
XRCiZ™ feature is disabled. 
NOTE: LED feedback is not available when using RCL-100 or URC-101 Point Pads™. 
NOTE: The searchlight should not be covered while the XRCiZ™ feature is enabled. 
The URC-102 Master  Controller  provides optimum  voltage to  ensure  the brightest 
searchlight  performance  and  long  bulb  life.  Also  to  extend  lamp  life,  the  Master 
Controller  has  a  timed  lamp  power  up  feature.  The  searchlight lamp  reaches full 
intensity within 2 seconds. 
The  URC-102  Master  Controller  has  a  searchlight  motor  timeout  feature. If  a Point 
Pad™ rotation switch (right or left) is continuously engaged for more than 50 seconds, 
the  Master  Controller  will  interrupt  the  operation  until  the  Point  Pad™  switch  is 
disengaged. This feature will save the searchlight motor from burnout due to accidental 
activation. The elevation motor has similar features which will timeout in approximately 
20 seconds. 