Specifications
Y1-03-0141F  5 
SECTION 4 - REMOTE CONTROL SYSTEM 
The Remote Control System consists of the URC-102 Master Controller and the URP-
102 Point Pad™. This system is compatible with 12 VDC and 24 VDC systems without 
modification. The remote control system may be used with 12 V or 24 V searchlights, 
Only the lamp in the light head assembly must be changed to match the voltage rating. 
SECTION 5 - URP-102 POINT PAD™ 
Case Options 
The URP-102 Point Pad™ is supplied as a surface mount unit (see  Figure 4). A flush 
mount option is provided (see Figure 5). To switch mounting options, unscrew the six 
(6) screws on the unit’s back plate and remove the front cover. Fit the Point Pad™ with 
the flush mount cover, replace the back plate, and screw the unit back together. 
Mounting 
Both the surface mount and flush mount options require access to the backside of the 
mounting  location. Make  sure  there  are  no  obstructions  behind  the  area  where  the 
switch  is  to  be  located  (e.g.  bulkheads,  wires,  plumbing, or  hardware).  Check  in 
advance that the coax cable from the master controller can be routed to this location. 
Generally, the Point Pad™ should be mounted in a protected area. 
Install the surface mount Point Pad™ by drilling three (3) holes in the dashboard 
location using the Point Pad™ surface mount template supplied. Mount the Point Pad™ 
to the dashboard using the gasket, washers, and nuts supplied. Use a sealant around 
the bolt holes to protect from moisture intrusion. 
When the  flush mount option  is  selected, cut  a rectangular hole  in the  dashboard 
location using the point pad™ flush mount template supplied in the mounting templates. 
Use  the  gasket,  washers,  nuts,  and  the  two  U-clamps  provided  to  secure  the  Point 
Pad™. Use a sealant around the cut out to protect from moisture intrusion. 
Connecting to the Master Controller 
The Point Pad™ communicates with the Master Controller via standard television type 
RG-59 coaxial cable. The connectors are standard "F" type television connectors. The 
connector on the back of the Point Pad™ is located in the center of the panel for ease 
of installation. After the coax cable has been routed and the “F” connectors attached to 
the coax cable, simply screw the “F” connectors to the Master Controller and the Point 
Pad™.  The  cable  and connectors  are available  either through  ACR Electronics, your 
local Radio Shack or other sources of electronic hardware.   