Owner's manual

Revision: 1.0
64
origin point
7
Accept command and send
interrupt.
0 = Command execute
incompletion, 1 = Run Next
Command Mode
Yes Ye s
0
REEL B Feedback Pattern Register (91h & 92h)
Bit Field Description
Software
Readable
Software
Writable
Value
after
Reset
0 - 15 Yes Yes 0
REEL B Lamp Register (93h)
Bit Field Description
Software
Readable
Software
Writable
Value
after
Reset
0
Outer LAMP Commom Control.
0 = Sourcing Mode, 1 = Sinking
Mode
Yes Ye s 0
1
Inner LAMP Commom Control.
0 = Sourcing Mode, 1 = Sinking
Mode
Yes Ye s 0
2
LAMP0 Control.
1 = Light in Sourcing Mode; Dark
in Sinking Mode,
0 = Dark in Sourcing Mode; Light
in Sinking Mode
Yes Ye s 0
3
LAMP1 Control.
1 = Light in Sourcing Mode; Dark
in Sinking Mode,
0 = Dark in Sourcing Mode; Light
Yes Ye s 0