Specifications

ADT60/AET60 Reference Manual version 1.5 November 2005
8.1.6 SET_PPS_MODE
This command selects the PPS mode to be used
Command format
Instruction Code Data length Data
PPS_Mode
07
H
01
H
NOTIFY Specifies whether the Card Status Message shall be transmitted to notify the host computer of
card insertion / removal
00
H
: baud rate to/from the card is from 9600 bps to 115200 bps (default)
01
H
: baud rate to/from the card is at 9600 bps only
Response data format
No response data
8.2 Card Commands (MCU-based Card)
The available commands and the parameters specified in the card commands as well as the data
transmitted in the response from the BioCARDKey/BioSIMKey depend on the selected card type.
8.2.1 RESET
This command powers up the card inserted in the card reader and performs a card reset. If the card is
powered up when the command is being issued, only a reset of the card is carried out. The power supply to
the card is not switched off.
Command format
Instruction Code Data length
80
H
00
H
Response data format
ATR
ATR Answer-To-Reset as transmitted by the card according to ISO7816-3.
NOTE - The ATR is only returned in the BioCARDKey/BioSIMKey response if the communication protocol of the card is compatible
with the reader, i.e., if the card can be processed by the BioCARDKey/BioSIMKey. Otherwise, the BioCARDKey/BioSIMKey returns an
error status and deactivates the smart card interface.
Advanced Card Systems Ltd. Page 19 of 25