5. Power Supply
The BioCARDKey/BioSIMKey requires a voltage of 5V DC, 100mA, and regulated, power supply. The
BioCARDKey/BioSIMKey gets the power supply from the PC through the cable supplied along with the
device.
Status LEDs
Red LED on the front of the reader indicate the activation status of the smart card interface:
Red LED Indicates power supply to the smart card is switched on, i.e., the smart card is activated.
6. USB Interface
The BioCARDKey/BioSIMKey is connected to a computer through a USB following the USB standard.
6.1 Communication Parameters
The BioCardKey/BioSIMKey is connected to a computer through USB as specified in the USB Specification
1.1. The BioCARDKey/BioSIMKey is working in full speed mode, i.e. 12 Mbps.
USB Interface Wiring
Pin Signal Function
1 V
BUS
+5V power supply for the reader
2 D-
Differential signal transmits data between BioCARDKey/BioSIMKey and
PC.
3 D+
Differential signal transmits data between BioCARDKey/BioSIMKey and
PC.
4 GND
Reference voltage level for power supply
NOTE - In order for the BioCARDKey/BioSIMKey to function properly through the USB interface, ACS PC/SC device driver has to be
installed. Please refer to the BioCARDKey/BioSIMKey Device Driver Installation Guide for more detail.